HEATER COMPARTMENT CLEARANCES 

(see BS 5864)

6.1 

 IMPORTANT

 - If the heater is to be fitted to an existing base duct (warm air plenum), always ensure when 

installing the appliance, the rear left hand corner of the heater is aligned with the rear left hand corner of the 
base duct. If there is any overhang or blanking off it will be at the front or right hand side of the heater. In any 
event, blanking plates must be mechanically secured and all joints sealed.

6.2  

When the heater is fitted into a compartment, a minimum clearance from the compartment walls of 38mm 
(1½”) at the rear, 75mm (3”) total at the sides (with a minimum of 25mm (1”) at any one side), and 63mm 
(2½”) at the front must be left. Consideration should also be given to the space required for the removal and 
replacement of the filter tray and the entry of the gas and electrical supplies.

6.3  

For service access, a minimum of 600mm (24”) is required at the front of the heater. Space must also be allowed, 
in a compartment installation, to permit the removal of the heater. The clearance between the appliance and 
the compartment should be not less than 75mm (3”). However, if clearances are less than 75mm, the  internal 
surface of the compartment must be lined with non-combustible material and the compartment must be of 
a fixed rigid structure.

6.4  

In airing cupboard installations, the part used as the air heater compartment must comply with the relevant 
section of BS 5864 and must be completely separated by either a non-combustible partition or a perforated 
metal partition with the perforations not exceeding 13mm (½”). The secondary flue must be a tight fit where 
it passes through the partition and must be suitably protected (see BS 5440: Part 1).

6.5 

In under-stairs installations, the compartment must comply with the relevant section of BS 5864, provided 
that in addition all internal surfaces (including the base) are non-combustible or lined with non-combustible 
material. This requirement is applicable only to dwellings of  more than two storeys.

6.6 

Where the air heater is to be installed onto a combustible surface and under-floor ducting used, a suitable 
base tray (BT65/90) MUST be used in order to provide insulation. 

 

NB: Where a base plenum is used no base tray is required!

5. 

TECHNICAL DATA

TABLE 1

ECONOMAIRE 65

ECONOMAIRE 65

INTEJAN

WEIGHT

48kg

86kg

GAS

G20

GAS SUPPLY PRESSURE

20mbar

GAS CATEGORY

I 2 H

COUNTRIES OF INSTALLATION

GB & IE

ELECTRICAL SUPPLY

230v ~ 50Hz fused 5A (150 watts)

NOx Class

1

MAXIMUM WATER SIDE 
OPERATING PRESSURE (PMS)

n/a

3 bar

OPEN VENTED SYSTEM

n/a

YES

SEALED SYSTEM

n/a

YES

AIR HEATER

WATER CIRCULATOR

MINIMUM

MAXIMUM

KW

MJ/h

Btu/h

KW

MJ/h

KW

KW

MJ/h

Btu/h

INPUT (GROSS)

21.6

77.6

73,550

25.0

90.0

85,302

4.86

17.5

16,600

OUTPUT

16.1

58.0

55,000

19.1

68.6

65,000

3.5

12.6

11,900

GAS RATE CV 1037Btu/FT³

2.05m

3

/h (72.62ft

3

/h)

2.38m

3

/h (84.22ft

3

/h)

0.458m

3

/h (16.2ft

3

/h)

BURNER SETTING PRESSURE (HOT)

11.5mbar (4.6 in wg)

15.5mbar (6.2 in wg)

15.0mbar (6.0 in wg)

MAIN INJECTOR

Bray Cat 23/850

Amal 187/001/400

CROSS-LIGHTER INJECTOR

Bray Cat 10/60

Содержание 42-416-18

Страница 1: ...IONING SERVICING INSTRUCTIONS ECONOMAIRE 65 Warm Air Heater with Intejan Water Circulator Economaire 65 G C No 42 416 18 Intejan Water Circulator G C No 42 416 99 These instructions are to be left wit...

Страница 2: ...4 Safety Gas Information 4 General Safety Information Gas Categories Gas Supply 5 Technical Data 5 6 Heater Compartment Clearances 5 7 Ventilation Air 6 8 Duct System 6 Return Air Warm Air Delivered 9...

Страница 3: ...irculator multifunction control 16 Flue gas test point 17 LED diagnostics indicator 18 Control module 19 Filter 20 Flue adapter 21 4 to 5 flue enlarger 2 GENERAL DESCRIPTION 2 1 The ECONOMAIRE 65 INTE...

Страница 4: ...appliance is CE certificated for safety and performance It is important that no modifications are made to this appliance unless fully approved in writing by Johnson Starley Ltd If in doubt please rin...

Страница 5: ...with the relevant section of BS 5864 and must be completely separated by either a non combustible partition or a perforated metal partition with the perforations not exceeding 13mm The secondary flue...

Страница 6: ...valent of 300mm x 300mm 12 x 12 If flexible duct is used the duct diameter should not be less than 350mm 16 dia The return air grille should have a free area of not less than 1593cm2 291in2 8 1 3 An a...

Страница 7: ...ed directly on top of the flue adaptor The heater can be used with horizontal or vertical flue types C12 and C32 9 5 1 All joints must be soundly sealed 9 5 2 Sufficient support brackets must be used...

Страница 8: ...pes 75mm E Below eaves 200mm F Below balconies 200mm G From a vertical drain pipe or soil pipe 150mm H From an internal or external corner Greater than 450mm protrusion 300mm I Above ground roof or ba...

Страница 9: ...omponents type TGD1111105 guard or similar such that the distance between the guard and the nearest part of the terminal is no less than 50mm 9 6 8 Reference should be made to Table 2 for required ter...

Страница 10: ...ical Terminal Support Bracket 1 1000 0016630 Terracotta 7 Lead Pitched Roof Flashing Collar 1 1000 0014890 Anthracite 8 Lead Pitched Roof Flashing Collar 1 1000 0014990 Terracotta 9 Aluminium Flat Roo...

Страница 11: ...wires to terminals 8 and 9 on the terminal block see Figures 17 18 11 GAS See BS 5864 and BS 6891 11 1 1 The local gas supply conditions MUST be adequate for the specified burner pressures as stated...

Страница 12: ...both the AIR HEATER and WATER HEATER switches on the time control unit to the OFF position 13 2 3 Set the thermista stat to 9 13 3 4 Locate the LED status indicator which can be observed through the...

Страница 13: ...fter a short period ensure that the fan increases to full speed 13 5 4 When the temperature reaches the control setting check that the main burner cycles ON and OFF at intervals of approx 75 to 120 se...

Страница 14: ...82 C The temperature is increased by rotating the thermostat knob clockwise and temperature stop 2 MUST be left in position see Figure 11 If the circulator is used in a direct application ensuring a m...

Страница 15: ...he time control to CONT and observe the LED status indicator 15 2 7 Whilst the control module runs through its diagnostic cycle the decimal point DP in the bottom right hand corner of the LED display...

Страница 16: ...tructions are left taped to the air heater for the user s reference and that the installation instructions are left at or near the air heater for use on future service calls 16 2 If the building is oc...

Страница 17: ...stability and with the main burner lit ensure that the operation of the air circulation fan does not affect the main burner flame profile 17 1 12 Locate the flue gas test point and attach a flue gas a...

Страница 18: ...ng care to not disturb the balance of the fan 10 6 7 Refitting or replacement is in reverse order 10 7 CONTROL MODULE REMOVAL 17 7 1 Ensure that the electrical supply is isolated 17 7 2 Remove the fro...

Страница 19: ...e electrical supply is isolated 17 9 2 Remove the appliance front door 17 9 3 Remove the 2 x fixing screws holding the FDC limit switch assembly in place and withdraw from the appliance 17 9 4 Disconn...

Страница 20: ...s ONLY necessary to press the RESET button if the red LED is continually illuminated NOTE When the air heater and water circulator are used in combination the status indications for the water circulat...

Страница 21: ...21 Sales Spares Replacement Help Line 01604 762881 FIGURE 14 CONTROL FLOWCHART 19 FAULT FINDING...

Страница 22: ...www johnsonandstarley co uk 22 FIGURE 15 AIR HEATER DIAGNOSIS FLOWCHART...

Страница 23: ...23 Sales Spares Replacement Help Line 01604 762881 FIGURE 16 WATER CIRCULATOR FLOW CHART...

Страница 24: ...www johnsonandstarley co uk 24 20 LOGIC DIAGRAM FIGURE 17 LOGIC DIAGRAM...

Страница 25: ...25 Sales Spares Replacement Help Line 01604 762881 3 21 SCHEMATIC DIAGRAM FIGURE 19 SCHEMATIC DIAGRAM...

Страница 26: ...www johnsonandstarley co uk 26 FIGURE 19 SCHEMATIC DIAGRAM showing connection of an external controller 22 CIRCUIT DIAGRAM Showing connections of an external controller...

Страница 27: ...27 Sales Spares Replacement Help Line 01604 762881 FIGURE 20 ECONOMAIRE 65 DIMENSIONS 23 DIMENSIONS...

Страница 28: ...7000 Cabinet Door Assembly 1 22 E82823 J652 0525005 Air Circulation Fan 1 23 E05998 1000 0701260 Ignition Burner Injector 1 24 E69653 1000 1507310 Gasket 1 25 E69709 1000 0000390 Air Pressure Tube 2 2...

Страница 29: ...29 Sales Spares Replacement Help Line 01604 762881 25 EXPLODED DIAGRAM FIGURE 21 ECONOMAIRE 65 EXPLODED DIAGRAM...

Страница 30: ...m start control Heating zone control Fitted Not required WARM AIR HEATER Has the system been balanced in accordance with the heater manufacture s instructions Yes No Was an anemometer used Yes No Yes...

Страница 31: ...Company name Telephone No Gas safe register No Record At max rate CO ppm AND CO At min rate Where Possible CO ppm AND CO Comments Signature SERVICE 06 Date Engineer name Company name Telephone No Gas...

Страница 32: ...nson Starley Ltd Rhosili Road Brackmills Northampton NN4 7LZ sales johnsonandstarley co uk marketing johnsonandstarley co uk Reception Customer Service 01604 762881 Fax 01604 767408 Anniversary 1922 2...

Отзывы: