vision
Snack Plus/Easy Combo
//
Vending
MNP86V03GBV00
Date: 2010/06/14 Rev. 0
PAGE 57 OF 62
7.2. Jams and changes in the J-2000 compact tubes
To disassemble the compact follow the steps below:
●
Empty the compact's tubes
completely.
●
Remove the front cover (1).
●
Loosen the selector by moving
the catch (2).
●
Remove the screws located in
the selector catch and on both
sides of the U-shaped plate (3).
Fig. 44
After these steps, place the compact on a
horizontal surface and remove the U-shaped
plate (see fig. 45).
Now the tubes can be accessed by moving
the coin separator assembly and display
sideways.
Once the necessary changes have been
made, follow the above steps in reverse order
to re-assemble the unit.
Fig. 45
7.3. Installing and removing channels
You can replace tray channels quite easily, as explained below. The channels are
adjustable and do not require any tools.
1. Check the location and type of channel to be installed, according to the product that
you wish to dispense.