Joerns Support Surface

DermaFloat LR Model

© 2015 Joerns Healthcare • 6110064 RevB • 15-2003

Shear and Friction Reduction

Shearing occurs when the skin is stationary in relation 

to the support surface, while the underlying tissues 

and vessels are stretched and damaged. When a 

resident’s skin rubs against another surface, the result 

is friction. The top surface of the DermaFloat LR 

therapy pad is constructed from a very smooth nylon 

fabric with low friction and low shear properties to 

protect the resident’s skin from these damaging forces.

Indications for Use

Note:

 The selection of a pressure-relieving surface 

needs to be based on each individual resident’s clinical 

condition, diagnosis and/or co-morbidities. The choice 

and use of a support surface is one factor in a holistic 

program of wound care  

and treatment.

Spinal Cord Injury

The DermaFloat LR is not recommended for use by 

residents with unstable spinal fractures. Advice should 

be obtained from the appropriate physician before 

using the DermaFloat LR system for these residents. 

Pressure Relief

Pressure 

Ulcers 

  Rehabilitation

Respiratory Conditions   

Neurology 

Dermatology    

 

Burns 

Amputations

Pain Management

AIDS    

 

Arthritis

Oncology

The DermaFloat

®

 LR provides distribution of weight 

over a wide surface area, which relieves pressure 

against bony prominences and provides a soft, gentle 

therapy surface to lie on. For residents experiencing 

severe pain and discomfort due to pressure and/or 

positioning limitations, consider the DermaFloat LR as 

an adjunct to pain management interventions.

Note:

 Pressure relief and pain management are 

conditions and diagnoses for which the DermaFloat LR 

may be indicated. Occasionally, there are orthopedic 

and neurological residents that require body 

positioning to be maintained in specific alignment. The 

use of the DermaFloat LR for these residents should 

be considered on an individual basis and discussed 

with the attending physician.

Joerns Healthcare 1_Art Direction_Joerns Beds_700 Series_UltraCare 8page

4/2007_Page 5 of 8

5

Introduction

The DermaFloat

®

 LR, provided by Joerns Healthcare, 

is a unique, continuous bilateral rotation mattress 

replacement system. This system is designed to 

assist in the effective management of residents at risk 

from the complications of immobility while providing 

low air loss therapy. Low air loss therapy has been 

demonstrated to reduce the risk of pressure ulcers 

as well as being a valuable aid in the treatment of 

pressure ulcers.

Warning: 

The risk of entrapment can arise when 

equipment is placed on bed frames that leave gaps 

of even a few inches between the mattress and the 

headboard, footboard, and bed or side rails. The 

equipment is NOT to be used when such gaps are 

present. See “Important Precautions” section of  

this manual.

The DermaFloat LR mattress replacement system is 

suitable for both the treatment of existing pressure 

ulcers stage I through stage IV as well as those who 

have been assessed at risk from the complications of 

immobility. The DermaFloat LR is quiet, comfortable 

and simple enough for single caregiver installation, 

featuring rapid inflation in just 15 minutes or less. The 

user-friendly controls allow for easy adjustment of 

resident comfort. 

Additionally, low friction and low shear materials, 

together with average interface pressures well below 

capillary closure levels, means that the DermaFloat LR 

meets the comfort and clinical requirements of your 

residents up to 350 lbs.

We have ensured that the DermaFloat LR addresses 

the four key areas in the treatment of compromised 

skin: pressure relief, moisture control, and reduction in 

both friction and shearing forces.

Moisture Control

Residents are at risk for skin maceration if excess 

moisture is permitted to accumulate beneath the 

resident. This may be due to perspiration, incontinence 

or wound drainage. 

On the DermaFloat LR, moisture is controlled via the 

specially treated breathable, fluid-proof, urethane 

coated nylon therapy pad. The moisture vapor 

permeable fabric of the therapy pad allows a sufficient 

amount of air to circulate beneath the pad and wicks 

away excess moisture.

Содержание DermaFloat LR

Страница 1: ...User Service Manual Joerns Support Surface DermaFloat LR Model To avoid injury read user s manual before using...

Страница 2: ...presence of smoking materials or open flame Air flowing through the air mattress will support combustion 2 Danger To reduce the risk of shock adhere to the following instructions Failure to do so cou...

Страница 3: ...manufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Jo...

Страница 4: ...ort Power Failure Low Pressure Alarm Optional Accessories Troubleshooting 9 10 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Control Troubleshooting Modes of Operation...

Страница 5: ...with the attending physician 5 Introduction The DermaFloat LR provided by Joerns Healthcare is a unique continuous bilateral rotation mattress replacement system This system is designed to assist in t...

Страница 6: ...of cleaning re assembly and cost effective service Lower two inch therapy support cell provides additional therapeutic support and remains inflated for up to 12 hours in the event of a power failure...

Страница 7: ...cal system with more reliable equipment If repair or replacement of the cord or plug is necessary please contact Joerns Healthcare for assistance 7 Setup Warning For important precautions please see p...

Страница 8: ...prior to Autofirm either Turn or Static in approximately 15 minutes Pause Use this feature to immediately stop all rotation and hold the current mattress position The mattress will hold this position...

Страница 9: ...e an audible alarm and will flash L and P on the display Once the low pressure condition has been corrected the alarm will cease and the control unit will return to normal operation Optional Accessori...

Страница 10: ...nent of urine and or stool and residents with heavily draining wounds Add top sheet blanket and or bedspread as needed for resident comfort Keep the amount of padding between the resident and bed to a...

Страница 11: ...age with possible body fluids it is recommend that the mattress system be cleaned with a mild detergent and warm water If disinfection is desired a combination cleanser disinfectant may be used as exp...

Страница 12: ...ithout Joerns s authorization will invalidate any warranties on this product Storage and Care Note Clean the DermaFloat LR as described in the previous section prior to storage Control Unit The power...

Страница 13: ...sive usage Improper maintenance handling and or cleaning Failure to use in the manner indicated in the DermaFloat LR user manual Any modification repair or alteration done to the DermaFloat LR that wa...

Отзывы: