Joerns

®

 Support Surfaces

DermaFloat

®

 APM

Save These Instructions for Future 

Reference

Bed System Entrapment Information

In April 1999, the U.S. Food and Drug Administration 

(FDA) in partnership with representatives from the 

hospital and post-acute bed industry, including 

Joerns Healthcare, national healthcare organizations, 

resident advocacy groups, and other federal agencies 

formed the Hospital Bed Safety Workgroup (HBSW). 

The workgroup’s goal is to improve the safety of 

bed frames for residents and patients in all health 

care settings who are most vulnerable to the risk of 

entrapment. The efforts of the FDA and the HBSW 

culminated in the FDA’s release of recommended 

guidelines intended to reduce the risk of entrapment, 

including dimensional limits for critical gaps and 

spaces between bed system components and clinical 

guidance for assessment and implementation of bed 

side rails in various health care settings.

Entrapment zones involve the relationship of 

bed components often directly assembled by the 

healthcare facility rather than the manufacturer. 

Therefore, compliance is the responsibility of  

the facility.

As the leading manufacturer of long-term care beds 

and a frontrunner in addressing this critical issue, 

Joerns Healthcare can offer you the expertise, 

assistance and products to bring your facility into 

compliance.

Joerns

®

 Compliance Solutions

Matching the right bed components in order to meet 

regulatory guidelines can be complex.

That is why Joerns offers a wide array of compliance 

options. We assist customers in selecting compliant 

accessories recommended for their specific bed 

model.

Creating a Safer Care Environment

While the guidelines apply to all healthcare settings 

(hospitals, nursing homes and home care), long-term 

care facilities have particular exposure since serious 

entrapment events typically involve frail, elderly or 

dementia residents.

For More Information

To learn more about compliance options with  

Joerns products, visit our website at www.joerns.com, 

 or contact our Customer Care representatives 

at 800.826.0270 and ask for free informational 

publications.

To learn more about entrapment zones, assessment 

methods, and guidelines concerning entrapment, 

contact Joerns Healthcare at 800.826.0270 or 

consult the FDA website: http://www.fda.gov/

MedicalDevices/ProductsandMedicalProcedures/

GeneralHospitalDevicesandSupplies/HospitalBeds/

default.htm.

Содержание DermaFloat APM

Страница 1: ...Joerns Healthcare User Service Manual Joerns Support Surface DermaFloat APM transforming wound management To avoid injury read user s manual before using...

Страница 2: ...presence of flammable anesthetics Do not use in the presence of smoking materials or open flame Air flowing through the air mattress will support combustion Danger To reduce the risk of shock adhere...

Страница 3: ...esponsibility of the facility As the leading manufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and produc...

Страница 4: ...when equipment is placed on bed frames that leave gaps of even a few inches between the mattress and the head panel foot panel and bed or side rails The equipment is NOT to be used when such gaps are...

Страница 5: ...ts should be considered on an individual basis and discussed with the attending physician Features The DermaFloat APM is comprised of two components Therapy control unit Therapy mattress system Therap...

Страница 6: ...though there is no ground wire There is always a chance of a loose connection or poor installation of a ground wire that causes the loss of proper ground at the outlet Inadequate grounding at electric...

Страница 7: ...de Operation Warning For important precautions see page two Caution The resident s head should be positioned in the center of the top section of the mattress When using the mattress system always ensu...

Страница 8: ...ll vary based on resident weight and profile To resume therapy reattach the hose to the control unit Figure 3 CairLock The mattress system comes equipped with our specially designed CairLock therapy c...

Страница 9: ...or the highest comfort control setting to achieve quick inflation Locate the Ready Valve by unsnapping the flap on the hose set Turn the Ready Valve to inflate or deflate as desired Return the control...

Страница 10: ...s of resident migration or inadvertent deflation of resident surface Skin Care Monitor skin conditions regularly particularly in areas where incontinence and drainage occur or collect and consider adj...

Страница 11: ...hands Therapy Pad The therapy pad can be wiped down with a disinfectant solution or a mild detergent with a damp cloth If heavily soiled the therapy pad can be laundered in a washer and dryer with wa...

Страница 12: ...ght must not exceed bed frame manufacturers specified load capacity Environmental Conditions Operating Conditions Ambient temperature 10 C to 40 C Relative humidity Non condensing Storage And Shipping...

Страница 13: ...13 Joerns Support Surfaces DermaFloat APM Notes...

Страница 14: ...essive usage Improper maintenance handling and or cleaning Failure to use in the manner indicated in the DermaFloat APM user manual Any modification repair or alteration done to the DermaFloat APM tha...

Отзывы: