SC4 M&S DAD Stereo Compressor - User's guide
SC4
11
INPUTS AND OUTPUTS
ANALOGUE INPUTS
Line inputs are 20Kohm floating balanced via XLR connectors maximum
level is 28dBu.
ANALOGUE OUTPUTS
Line outputs are XLR connectors 75 ohm source impedance, auto-centreing
balanced. Maximum 26dBu.
INSERT
An unbalanced port is provided so that additional analogue circuits may be
inserted into the sum and difference (MS) path.
The 'tip' is the buffered analogue output of the MS coder the 'ring' is the
input of the compressor
DIGITAL INPUTS AND OUTPUTS
All digital connections DC isolated from analogue systems.
TOSLINK Optical inputs and outputs.
AES/EBU XLR input and output.
POWER
Power input is 230 or 115VAC at approx 12 watts.
Voltage selection is by rotating the fuseholder.
NOTE. Operation of the compressor on the wrong mains voltage WILL