MAINTENANCE
175
MUX17JP021602
Boom
Lift
Models X17JPLUS
des.
This
condition
may
cause
serious
damage
to
the
respiratory
tract,
skin
and
eyes.
All
precautions
needed
to
limit
exposure
to
these
fumes
must
be
adopted.
It
should
be
noted
that
this
procedure
is
applicable
only
to
fires
on
individual
cel
‐
ls.
Larger
fires
have
to
be
managed
only
by
professionally
trained
personnel.
Fi
‐
nally,
it
should
be
noted
that
in
the
presence
of
combustible
materials
other
than
lithium
it
is
advisable
to
use
different
types
of
extinguishers
in
conjunction
to
bet
‐
ter
ensure
the
extinguishing
action
of
each
on
the
appropriate
material,
however
do
not
use
water
or
CO2
extinguishers
directly
on
lithium
fires.
MINIMUM
EQUIPMENT
REQUIRED:
• Class
D
fire
extinguisher
• Class
ABC
extinguisher
for
any
secondary
fires
• Breathing
apparatus
• Fireproof
clothing
• Fireproof
gloves
• Mask
or
protective
glasses
• Non
‐
conductive
pliers
• Dustpan,
mineral
oil
PROCEDURE:
• In
the
event
of
fire
on
one
cell,
a
team
of
experienced
fire
‐
fighting
personnel
has
to
be
contacted.
The
personnel
must
be
properly
trained
to
fight
lithium
bat
‐
tery
fires.
• Evacuate
personnel
from
all
areas
and
sound
the
fire
alarm.
• The
fire
‐
fighting
personnel
go
to
the
area
where
the
fire
is
located
and
gather
all
the
information
regarding
the
situation
and
the
person
who
gave
the
alarm.
• Quarantine
the
area.
Air
the
rooms
until
the
burning
material
has
been
remo
‐
ved
from
the
area
and
the
characteristic
pungent
odour
has
disappeared.
• Two
members
of
the
team
enter
the
area
with
appropriate
safety
equipment.
Lithium
melts
at
180°C.
It
becomes
highly
reactive
and
when
it
catches
fire
it
may
eject
molten
lithium
particles.
For
this
reason
the
surrounding
cells
may
overheat
and
cause
a
violent
explosion.
The
fire
‐
fighting
personnel
must
pay
attention
to
any
dangerous
materials
located
near
the
fire.
Completely
cover
the
fire
with
ex
‐
tinguishing
material.
Never
leave
the
fire
unattended
as
it
may
develop
again.
• If
necessary,
extinguish
the
secondary
fires
with
suitable
extinguishers.
• After
all
the
material
has
burned
and
cooled
down,
carefully
mix
the
residual
material
to
prevent
resumption
of
the
fire.
Содержание X17JPLUS
Страница 2: ......
Страница 8: ...MUX17JP021602 6 Boom Lift Models X17JPLUS ...
Страница 34: ...32 Boom Lift Models X17JPLUS TECHNICAL INFORMATIONS MUX17JP021602 ...
Страница 87: ...USING THE MACHINE 85 MUX17JP021602 Boom Lift Models X17JPLUS 11 3 WORKING AREA Fig 79 Working area ...
Страница 162: ...160 Boom Lift Models X17JPLUS MAINTENANCE MUX17JP021602 ...
Страница 189: ...HYDRAULIC SYSTEM 187 MUX17JP021602 Boom Lift Models X17JPLUS 15 HYDRAULIC SYSTEM Riferimento Descrizione 1 Hand pump ...
Страница 192: ...190 Boom Lift Models X17JPLUS WIRING DIAGRAM MUX17JP021602 16 WIRING DIAGRAM ...
Страница 193: ...WIRING DIAGRAM 191 MUX17JP021602 Boom Lift Models X17JPLUS Fig 172 Petrol ...
Страница 194: ...192 Boom Lift Models X17JPLUS WIRING DIAGRAM MUX17JP021602 Fig 173 Diesel ...
Страница 195: ...WIRING DIAGRAM 193 MUX17JP021602 Boom Lift Models X17JPLUS Fig 174 Lithium ...
Страница 197: ...WIRING DIAGRAM 195 MUX17JP021602 Boom Lift Models X17JPLUS Worldwide locations ...
Страница 198: ...196 Boom Lift Models X17JPLUS WIRING DIAGRAM MUX17JP021602 ...