SECTION 7 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS
7-12
3121781
Service - Voltage Reading
DO NOT PIERCE WIRE INSULATION TO TAKE VOLTAGE READINGS.
It has been common practice in electrical troubleshoot-
ing to probe wires by piercing the insulation with a
sharp point. This practice should be discouraged when
dealing with the AMPSEAL plug assembly, or any other
sealed connector system. The resulting pinholes in the
insulation will allow moisture to invade the system by
traveling along the wire strands. This nullifies the effec-
tiveness of the connector seals and could result in sys-
tem failure.
Figure 7-15. Connector Installation