SECTION 3 - CHASSIS, PLATFORM & SCISSOR ARMS
3-22
3121781
Troubleshooting
Table 3-3. Excessive Noise and/or Vibration
Item
Description
Action
Check oil level in reservoir and
oil supply to the motor.
Insufficient hydraulic fluid could lead to cavitation that would
cause system noise.
Fill the reservoir to the proper level and ensure that oil supply to
the motor is adequate and the lines are unobstructed.
Check for air in the system.
Air trapped within the system lines, or the motor itself, could result
in cavitation that would cause system noise.
Ensure that all of the system lines and components are purged of
air.
Inspect the output shaft cou-
plings.
A loose or incorrect shaft coupling will produce vibrations that
could result in system noise.
Ensure that the correct coupling is used and that it fits properly
onto the shaft.
Inspect the output shaft align-
ment.
Misaligned shafts create excessive frictional vibration that could
result in system noise.
Ensure that the shafts are properly aligned.
Hydraulic oil viscosity above
limits.
Viscosity above acceptable limits will result in cavitation that
would lead to system noise.
Replace hydraulic oil with appropriate fluid for operating condi-
tions.
Table 3-4. System Operating Hot
Item
Description
Action
Check oil level in reservoir and
oil supply to the pump.
Insufficient amount of hydraulic fluid will not meet the cooling
demands of the system.
Fill the reservoir to the proper level.
Inspect the heat exchanger, (if
so equipped).
If the heat exchanger fails, or becomes obstructed, it may not meet
the cooling demands of the system.
Ensure that heat exchanger is receiving adequate air flow and that
the heat exchanger is in good operating condition. Repair or
replace as necessary.
Check the system relief valves. If a system relief valve becomes unseated for an extended period of
time or fails for any other reason, the system could become over-
heated.
Repair or replace any malfunctioning relief valves as applicable
and verify that the loads on the machine are not excessive.
Table 3-5. Won’t Shift or Slow to Start
Item
Description
Action
Check the signal line to the
servo control port.
Obstructed or restricted flow through the servo control signal lines
could result in slow shift or no shift conditions within the motor.
Ensure that the signal lines are not obstructed or restricted and
that signal pressure is adequate to shift the motor.
Check that the correct supply
and drain orifices are properly
installed, and are not
obstructed.
Supply and drain orifices determine the shift rate of the motor. The
smaller the orifice, the longer the time it takes to shift the motor.
Obstruction will also increase shift times.
Ensure that the proper control orifices are installed in the motor
and verify that they are not obstructed. Clean or replace as neces-
sary.
Содержание 530LRT
Страница 2: ......
Страница 4: ...INTRODUCTION b 3121781 REVISION LOG Original Issue A September 03 2018...
Страница 14: ...x 3121781 TABLE OF CONTENTS This page left blank intentionally...
Страница 25: ...SECTION 1 SPECIFICATIONS 3121781 1 9 1 8 TORQUE CHARTS Figure 1 5 Torque Chart Sheet 1 of 5 SAE Fasteners...
Страница 26: ...SECTION 1 SPECIFICATIONS 1 10 3121781 Figure 1 6 Torque Chart Sheet 2 of 5 SAE Fasteners...
Страница 27: ...SECTION 1 SPECIFICATIONS 3121781 1 11 Figure 1 7 Torque Chart Sheet 3 of 5 SAE Fasteners...
Страница 28: ...SECTION 1 SPECIFICATIONS 1 12 3121781 Figure 1 8 Torque Chart Sheet 4 of 5 METRIC Fasteners...
Страница 29: ...SECTION 1 SPECIFICATIONS 3121781 1 13 Figure 1 9 Torque Chart Sheet 5 of 5 METRIC Fasteners...
Страница 30: ...SECTION 1 SPECIFICATIONS 1 14 3121781 NOTES...
Страница 110: ...SECTION 3 CHASSIS PLATFORM SCISSOR ARMS 3 68 3121781 NOTES...
Страница 261: ......