SECTION 5 - JLG CONTROL SYSTEM
3121781
5-23
5.7
MACHINE CONFIGURATION AND PROGRAMMING SETTINGS
The Machine Configuration Programming must be completed before any Personality settings
can be
changed. Changing the Personality settings
first and then changing the Model of the Machine Configuration will cause
the Personality settings to return to default values.
Table 5-3. Machine Configuration Programming Information
Configuration Digit
Setting
Description
Default Number
MODEL NUMBER:
1
0
1
2
330 LRT
430 LRT
530 LRT
2
MARKET:
2
0
1
2
3
4
5
ANSI USA
ANSI EXPORT
CSA
CE
AUSTRALIA
KOREA
0
ENGINE:
3
0
1
2
KUBOTA T4F
KUBOTA T4I
KUBOTA D/F
0
GLOW PLUGS:
4
0
1
2
3
NO GLOW PLUGS
5 SEC GLOW
10 SEC GLOW
20 SEC GLOW
3
LEVELING JACKS:
5
0
1
No - Leveling Jacks not installed on vehicle.
YES - Leveling Jacks are installed on vehicle.
1
GENERATOR:
6
0
1
NO - Generator is not installed on vehicle.
YES - Generator is installed on vehicle.
0
LOAD SYSTEM:
7*
0
1
2
NOT INSTALLED – No overload detection.
CUTOUT PLT – Platform controls are disabled when overloaded.
CUTOUT ALL – Platform and Ground controls are disabled when overloaded.
NOTE:
* Different Defaults by market: CE = 2
1
GROUND ALARM:
8*
0
1
2
NOT INSTALLED – Vehicle alarm will function for Overload (if LOAD enabled).
DESCENT – Vehicle alarm will function for Overload (if LOAD enabled) and during Lift Down
motion.
MOTION – Vehicle alarm will function for Overload (if LOAD enabled), during Drive
motion, and during Lift motion.
NOTE:
* Different Defaults by market: CE = 0
2
ENGINE SHUTDOWN:
9
0
1
NO - The engine will not be automatically shutdown.
SHUTDOWN - The engine will automatically shutdown in the event of high engine
coolant temperature, low oil pressure, or a temperature sensor or oil pressure sen-
sor fault.
1
LOW TEMP CUTOUT:
10
0
1
NO - The machine will not have low temperature cutout functionality.
YES - The machine is equipped with low temperature cutout capability for the CE and ANSI
EXPORT markets.
0
BEACON LIGHT:
11*
0
1
NO - The beacon light will never flash except for when being used by Electronic Arm
Guards (CE market). See footnote.
YES - The beacon light will flash at 1 Hertz all the time the machine is powered and not being
used by Electronic Arm Guards (CE market). See footnote.
NOTE:
* The beacon light will ALWAYS be used for unique visual indi-
cation (flash at 1 Hertz for 2 seconds, then off for 1 second) for
the Electronic Arm Guards feature (only equipped on CE mar-
ket) regardless of the BEACON LIGHT setting.
0
Содержание 530LRT
Страница 2: ......
Страница 4: ...INTRODUCTION b 3121781 REVISION LOG Original Issue A September 03 2018...
Страница 14: ...x 3121781 TABLE OF CONTENTS This page left blank intentionally...
Страница 25: ...SECTION 1 SPECIFICATIONS 3121781 1 9 1 8 TORQUE CHARTS Figure 1 5 Torque Chart Sheet 1 of 5 SAE Fasteners...
Страница 26: ...SECTION 1 SPECIFICATIONS 1 10 3121781 Figure 1 6 Torque Chart Sheet 2 of 5 SAE Fasteners...
Страница 27: ...SECTION 1 SPECIFICATIONS 3121781 1 11 Figure 1 7 Torque Chart Sheet 3 of 5 SAE Fasteners...
Страница 28: ...SECTION 1 SPECIFICATIONS 1 12 3121781 Figure 1 8 Torque Chart Sheet 4 of 5 METRIC Fasteners...
Страница 29: ...SECTION 1 SPECIFICATIONS 3121781 1 13 Figure 1 9 Torque Chart Sheet 5 of 5 METRIC Fasteners...
Страница 30: ...SECTION 1 SPECIFICATIONS 1 14 3121781 NOTES...
Страница 110: ...SECTION 3 CHASSIS PLATFORM SCISSOR ARMS 3 68 3121781 NOTES...
Страница 261: ......