SECTION 3 - TROUBLESHOOTING
3121804
– JLG Lift –
3-9
No voltage present at function control switch
Check wiring from power switch to function control
switch for proper connection or damage. Repair or
replace wiring as necessary
Defective function control switch
Replace function control switch
No voltage present at applicable control valve coil Check applicable wire for proper connection at
terminal strip, valve harness plug pin, valve har-
ness receptacle pin and valve coil. Using suitable
test meter, perform continuity test on wire. Repair
or replace harness as necessary
No voltage supplied to motor from start relay
Check battery cable from relay to motor for proper
connection or damage. Repair or replace cable as
necessary
Defective motor/pump assembly
Replace motor/pump assembly
ENGINE STARTER SYSTEM
Engine will not crank
Discharged battery or loose battery terminals
Check and charge battery or replace battery as
necessary. Clean and secure battery terminals
Starter relay faulty or faulty relay connections
Using a test meter, check relay coil terminals for
presence of electrical power and for energization
of relay coil. Also check relay terminals for correct
switching of contacts. Replace relay as necessary
Malfunctioning starter solenoid or motor
Replace solenoid or motor in accordance with
applicable manufacturer’s manual
Defective start lockout solenoid
Replace start lockout solenoid
Malfunctioning ignition switch
Using a test meter, check ignition switch for cor-
rect switching of contacts. replace switch as nec-
essary
Faulty ignition and/or starter circuit wiring
Check wiring continuity. refer to wiring diagram
Defective ring gear or flywheel
Replace ring gear
INSTRUMENTS AND INDICATORS
Ammeter inoperative
Damaged wiring in circuits
Repair or replace wiring
Ammeter not functioning properly
Replace ammeter
Alternator not charging
Repair or replace alternator
Travel warning horn inoperative
Circuit breaker open
Determine and correct cause
Damaged wiring in horn circuit
Replace horn
Hourmeter inoperative
Damaged wiring in hourmeter circuit
Repair or replace wiring
Inoperative hourmeter
Replace hourmeter
Table 3-4. Electrical System Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY
Содержание 330CRT
Страница 1: ...Service Maintenance Manual Model 330CRT 400CRT 3121804 April 7 2004 ...
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS iv JLG Lift 3121804 This page left blank intentionally ...
Страница 12: ...SECTION 1 SPECIFICATIONS 1 4 JLG Lift 3121804 Figure 1 1 Torque Chart ...
Страница 20: ...SECTION 2 PROCEDURES 2 6 JLG Lift 3121804 Figure 2 1 Arms and Platform Positioning and Support Cylinder Repair ...
Страница 22: ...SECTION 2 PROCEDURES 2 8 JLG Lift 3121804 Figure 2 3 400CRT LIft Cylinder ...
Страница 54: ...SECTION 3 TROUBLESHOOTING 3 12 JLG Lift 3121804 Figure 3 3 Hydraulic Schematic Sheet 1 of 2 ...
Страница 55: ...SECTION 3 TROUBLESHOOTING 3121804 JLG Lift 3 13 2792397 E Figure 3 4 Hydraulic Schematic Sheet 2 of 2 ...
Страница 56: ...SECTION 3 TROUBLESHOOTING 3 14 JLG Lift 3121804 This page intentionally left blank ...
Страница 57: ......