background image

 | Fathom 

IWS

Page 16

Route the Speaker Cable

Route speaker cable into the 

bottom of the wall cavity through 

an adjacent stud and remove the 

outer jacketing to expose the 

individual wires. Two rubber covers 

are included to insulate the speaker 

terminals. Feed the individual 

wires through each rubber cover 

and remove the wire insulation. 

While observing correct polarity, 

connect the individual wires to the 

push terminals located at the bottom 

of the enclosure, then slide a rubber 

cover over each terminal.  

(Figure 20-22)

Note: To reduce the potential 

for unwanted noise and vibration, 

position the individual wires so 

they do not come into contact with 

any surrounding parts (enclosure, 

mounting brackets, studs, wallboard 

surfaces or any other surfaces within 

the wall cavity). Any contact point 

may lead to undesirable rattles or 

buzzing, which will be inaccessible 

once the surrounding wallboard has 

been installed.

Figure 21

Figure 20

Figure 22

Содержание FATHOM IWS-SYS-108

Страница 1: ...Enclosure Installation Manual IWS SYS 108 IWS SYS 208...

Страница 2: ......

Страница 3: ...place candles nearby 6 Object or Liquid Entry Care should be taken so that objects do not fall into and liquids are not spilled onto the enclosure subwoofer or grille Do not expose to dripping or spla...

Страница 4: ...we strongly recommend reading these instructions completely before beginning the installation process Please note these instructions are for the installation of one 1 IWS enclosure Simply repeat the s...

Страница 5: ...applied to specific areas allowing it to only make gentle contact with its surrounding wallboard surfaces The placement and amount of pressure applied by these pads is a critical design aspect to ens...

Страница 6: ...sembly have been painted and the room s interior is free of construction debris A plastic paint guard is included to shield the inner black section of the grille tray from overspray during painting Th...

Страница 7: ...er system in home theater and home audio systems Utilizing a precisely engineered switching power supply the SA 600W is capable of efficiently generating unclipped output voltages equivalent to 600 wa...

Страница 8: ...are for the installation of one 1 enclosure Simply repeat the steps to install additional enclosures TOOLS FOR INSTALLATION Below is a list of recommended tools to perform the installation of the Fath...

Страница 9: ...s x4 Terminal Covers x2 Foam Gasket x1 1 00 2 00 1 25 8 x 1 inch Pan Head Screws x22 1 00 2 00 1 25 8 x 2 inch Pan Head Screws x8 1 00 2 00 1 25 8x1 25 inchWaferHeadScrews x30 Part A Wallboard Templat...

Страница 10: ...n Evaluating the Wall Cavity The IWS 108 enclosure is designed to mount in between two studs within the wall cavity so anything coming into contact with it can lead to unwanted vibrations and rattles...

Страница 11: ...ll four 8 x 1 25 inch wafer head screws to attach the Enclosure Floor Stand Part D to the Wallboard Template Part A Figure 1 Test Fit Enclosure Place the enclosure into the wall cavity with both Stud...

Страница 12: ...et on the top of the enclosure with its foam padded section positioned against one stud Mark a line along the L Bracket s edge to note its position Repeat this procedure for the L Bracket on the oppos...

Страница 13: ...er the pilot holes Select two non adjacent pilot holes within each slotted opening one to two holes apart and fully install two 8 x 1 inch pan head screws Then partially back out each screw leaving ju...

Страница 14: ...e wall cavity Centering the enclosure s position within the wall cavity so that no sides of the enclosure are in contact with the studs will reduce the potential for unwanted noise and vibration Insta...

Страница 15: ...slotted openings of the bottom L Brackets Figure 15 16 Lock the position of the bottom L Brackets by installing a 8 x 1 inch pan head screw into one of the two holes located in between the slotted op...

Страница 16: ...connect the individual wires to the push terminals located at the bottom of the enclosure then slide a rubber cover over each terminal Figure 20 22 Note To reduce the potential for unwanted noise and...

Страница 17: ...late Part A as a hard edge The surrounding wallboard should be installed flush against the wallboard template on all four sides Figure 25 Note It is critical that any gaps between the wallboard templa...

Страница 18: ...included with the grille assembly to fit a range of wallboard thicknesses It is critical to use the correct thumb screw length for a proper fit Refer to the table at right to select the thumb screw le...

Страница 19: ...ure Tighten each thumb screw by hand being careful not to over tighten Figure 3 Rubber screw stoppers are included to prevent the thumb screws from loosening To install press a rubber stopper over eac...

Страница 20: ...IWS SYS 208 Enclosure Type Single Ported Enclosure Two Ported Enclosures Driver s 8 in nominal diameter 8 in nominal diameter in each of two enclosures Frequency Response anechoic 24 9 Hz 109 Hz 1 5...

Отзывы: