9. Testing
Type tests
These tests are carried out by the Engineering Test Institute, Public Enterprise in
Brno, test room 202, Hudcova 56b, 621 00 Brno.
Production tests
These tests are carried out at production plant JINOVA s.r.o., Do Žlábku 733,
Jilemnice on each produced heat exchanger unit.
The following tests and checks are carried out in terms of production tests:
- cabinet welds check
- heat exchanger welds check
- external connection dimensions check
- surface treatment check
- check of completeness of the device and accessories
- check of electrical connection
See: “Unit test report”
Packaging, transport and storage
-
Supplied heaters are packaged on the request of the customer in a fixation foil to
reduce damage of the surface treatment and are stored on wooden prisms or
pallets.
-
It is necessary to ensure careful handling during transport and loading. Handling
must be carried out only via the pallet, the lower frame (between the wooden
prisms) or the welded loop. If there are two loops on the device, it is necessary to
use both of them, suspension on one loop is not permitted! Packaging must not be
exposed to direct influences of weather, long-term exposure to humidity and
impacts.
-
Storage of heaters must be carried out in well-ventilated rooms without the effects
of corrosive vapours and aggressive gases or under a shelter that safely covers the
heater against atmospheric precipitation.
INSTRUCTIONS FOR INSTALLATION
Installation of the heater in place
The heater is placed on a horizontal, solid enough floor or frame. It is necessary to
keep the horizontal position of the heater, or slight slope towards the condensate
outlet to ensure its easy drainage. The slope must not be greater than 5 mm in
width of the heater. The location must be such as to allow the combustion chamber to be
replaced and the tube space to be cleaned. This means that at the front (on the side of the
burner) there must be free space equal to the dimensions “length x width x height” of the
heater. On the panel covering the tube plate of the heat exchanger chamber (opposite the
chimney), nothing can be installed there due to dismantling when cleaning the tube plate.