5.2. Electrical specifications of JKMxxxM-72 and JKMxxxM-72B 
(xxx=250-320) Series polycrystalline solar modules 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Module Type 

JKM- 

250M 

-72 

JKM- 

255M 

-72 

JKM- 

260M 

-72 

JKM- 

265M 

-72 

JKM- 

270M 

-72 

JKM- 

275M 

-72 

JKM- 

280M 

-72 

JKM- 

285M 

-72 

JKM- 

290M 

-72 

JKM- 

295M 

-72 

JKM- 

300M 

-72 

JKM- 

305M 

-72 

JKM- 

310M 

-72 

JKM- 

315M 

-72 

JKM- 

320M 

-72 

JKM- 

250M 

-72B 

JKM- 

255M 

-72B 

JKM- 

260M 

-72B 

JKM- 

265M 

-72B 

JKM- 

270M 

-72B 

JKM- 

275M 

-72B 

JKM- 

280M 

-72B 

JKM- 

285M 

-72B 

JKM- 

290M 

-72B 

JKM- 

295M 

-72B 

JKM- 

300M 

-72B 

JKM- 

305M 

-72B 

JKM- 

310M 

-72B 

JKM- 

315M 

-72B 

JKM- 

320M 

-72B 

Maximum Power at 

STC(Pmax) 

250 

Wp 

255 

Wp 

260 

Wp 

265 

Wp 

270 

Wp 

275 

Wp 

280 

Wp 

285 

Wp 

290 

Wp 

295 

Wp 

300 

Wp 

305 

Wp 

310 

Wp 

315 

Wp 

320 

Wp 

Maximum Power 

Voltage (Vmp) 

34.8V 

35.0V 

35.3V 

35.6V 

35.9V 

36.1V 

36.3V 

36.5V 

36.7V 

36.8V 

37.0V 

37.2V 

37.4V 

37.6V 

37.8V 

Maximum Power 

Current (Imp) 

7.18A 

7.29A 

7.37A 

7.44A 

7.52A 

7.62A 

7.71A 

7.81A 

7.90A 

8.02A 

8.11A 

8.20A 

8.29A 

8.38A 

8.47A 

Open-circuit Voltage 

(Voc) 

43.4V 

43.6V 

43.9V 

44.1V 

44.4V 

44.6V 

44.8V 

45.0V 

45.2V 

45.3V 

45.5V 

45.7V 

45.9V 

46.1V 

46.3V 

Short-circuit Current 

(Isc) 

7.84A 

7.92A 

7.99A 

8.07A 

8.15A 

8.23A 

8.32A 

8.40A 

8.47A 

8.55A 

8.64A 

8.72A 

8.80A 

8.87A 

8.95A 

Maximum system 

Voltage 

1000VDC 

Dimensions 

1956x992x40mm(77.01×39.05 x1.57 inch) 

Maximum series 

overcurrent protective 

device rating(A) 

15A 

Содержание JKMxxxM-60 Series

Страница 1: ...JinkoSolar Photovoltaic Module User Manual UL1703 ...

Страница 2: ...stallation safety 2 2 Installation Condition 2 3 Mechanical Installation introduction 2 2 1 Climate condition 2 2 2 Site selection 2 3 1 Fixation with screws 2 3 2 Fixation with clamps 2 2 3 Tilt angle selection 3 Wiring and connection 4 Maintenance and care 5 Electrical specification 6 Disclaimer of Liability 21 7 Contact us Edition 03 2015 ...

Страница 3: ...solar module as listed below UL1000V JKMxxxP 72 xxx 250 320 in increment of 5 JKMxxxM 72 xxx 250 320 in increment of 5 JKMxxxP 60 xxx 200 265 in increment of 5 JKMxxxM 60 xxx 200 280 in increment of 5 JKMxxxPP 72 xxx 250 320 in increment of 5 JKMxxxPP 60 xxx 200 265 in increment of 5 JKMxxxP 72 J4 xxx 250 320 in increment of 5 JKMxxxP 60 J4 xxx 200 265 in increment of 5 JKMxxxP 72B xxx 250 320 in ...

Страница 4: ...this application class are considered to meet the requirements of Safety Class II The Fire rating is Class C in Canada but the Module Fire performance is type 1 in America with the specified construction in below table when used with a listed mounting system that has been rated as a Class A System when installed with type 1 modules is suitable to maintain the System Class A Fire Rating in America ...

Страница 5: ... A module with exposed conductive parts is considered to be in compliance with UL 1703 only when it is electrically grounded in accordance with the instructions presented below and the requirements of the National Electrical Code Any module without a frame laminate shall not be considered to comply with the requirements of UL 1703 unless the module is mounted with hardware that has been tested and...

Страница 6: ...uated through the requirements in UL 1703 may be used for grounding connections in accordance with the instructions provided with the module Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions The requirements of the National Electrical Code NEC in Article 690 shall be followed to addres...

Страница 7: ...lways wear protective head gear insulating gloves and safety shoes with rubber soles Keep the PV module packed in the carton until installation Do not touch the PV module unnecessarily during installation The glass surface and the frame may be hot There is a risk of burns and electric shock Do not work in rain snow or windy conditions Due to the risk of electrical shock do not perform any work if ...

Страница 8: ... operation don t use sharp tools to wipe the back sheet and glass it would leave scratch on the module Do not drill holes on the frame it may cause corrosion of the frame For roof mounting structure when install the modules please try to follow the from top to bottom and or from left to right principle and don t step on the module that will damage the module and would be dangerous for personal saf...

Страница 9: ...ls When solar modules are used to charge batteries the battery must be installed in a manner which will protect the performance of the system and the safety of its users Follow the battery manufacturer s guidelines concerning installation operation and maintenance recommendations In general the battery or battery bank should be away from the main flow of people and animal traffic Select a battery ...

Страница 10: ...The System Fire Class Rating of the module or panel in a mounting system in combination with a roof covering complete with requirements to achieve the specified System Fire Class Rating for a non BIPV module or panel Any module or panel mounting system limitations on inclination required to maintain a specific System Fire Class Rating 2 3 Mechanical Installation introduction Solar PV modules usual...

Страница 11: ...hers and the like have not been evaluated for electrical conductivity or for use as grounding devices and should be used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices where supplied with the module and evaluated through the requirements in UL 1703 may be used for grounding connections in accordan...

Страница 12: ...module frame is not to be modified under any circumstances When choosing this type of clamp mounting method please be sure to use at least four clamps on each module two clamps should be attached on each long side of the module The applied torque should be big enough to fix it steadily about 8 N m for safety you d better follow the clamps manufacture s recommendation Please find detailed mounting ...

Страница 13: ...XXP 72 JKMXXXPP 72 JKMXXXP 72B JKMXXXPP 72B JKMXXXP 72 J4 Poly 6 12 1956 992 400 480 5 11 0 5 2mm 14 2mm JKMXXXM 72 JKMXXXM 72B Moly 6 12 1956 992 400 480 5 11 0 5 2mm 14 2mm JKMXXXP 60 JKMXXXPP 60 JKMXXXP 60B JKMXXXPP 60B JKMXXXP 60 J4 Poly 6 10 1650 992 400 420 5 10 0 5 2mm 14 2mm JKMXXXM 60 JKMXXXM 60B Moly 6 10 1650 992 400 420 5 10 0 5 2mm 14 2mm ...

Страница 14: ...21 1000V 45 7V 21 8 c PV module connect in parallel should have similar voltage As reference the maximum number of modules in parallel M can be easily calculated by dividing the maximum rated current indicated in the electrical specification below by Isc value of the module and then plus 1 Any more please always take into consideration the variation of the current under different temperatures the ...

Страница 15: ...mmended that the screw be tightened to a torque of about 8 Nm j The cable of the junction box is defined as L1 as showed below For Jinko standard module L1 is 900 1200mm and for customized module L1 can be based on your condition take the cable length into consideration before designing the wiring layout 4 Maintenance and care a A built up of dust or dirt on the module s front face will result in ...

Страница 16: ... less voltage or current than rating value in uncertainty condition Accordingly the values of ISC and VOC marked on the module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the PV output Tables below are electrical characteristics of PV products at STC and the tolerance of Isc Voc Vmp and I...

Страница 17: ...JKM 310P 72B JKM 315P 72B JKM 320P 72B JKM 250PP 72B JKM 255PP 72B JKM 260PP 72B JKM 265PP 72B JKM 270PP 72B JKM 275PP 72B JKM 280PP 72B JKM 285PP 72B JKM 290PP 72B JKM 295PP 72B JKM 300PP 72B JKM 305PP 72B JKM 310PP 72B JKM 315PP 72B JKM 320PP 72B Maximum Power at STC Pmax 250 Wp 255 Wp 260 Wp 265 Wp 270 Wp 275 Wp 280 Wp 285 Wp 290 Wp 295 Wp 300 Wp 305 Wp 310 Wp 315 Wp 320 Wp Maximum Power Voltag...

Страница 18: ...at STC Pmax 250 Wp 255 Wp 260 Wp 265 Wp 270 Wp 275 Wp 280 Wp 285 Wp 290 Wp 295 Wp 300 Wp 305 Wp 310 Wp 315 Wp 320 Wp Maximum Power Voltage Vmp 34 8V 35 0V 35 3V 35 6V 35 9V 36 1V 36 3V 36 5V 36 7V 36 8V 37 0V 37 2V 37 4V 37 6V 37 8V Maximum Power Current Imp 7 18A 7 29A 7 37A 7 44A 7 52A 7 62A 7 71A 7 81A 7 90A 8 02A 8 11A 8 20A 8 29A 8 38A 8 47A Open circuit Voltage Voc 43 4V 43 6V 43 9V 44 1V 44...

Страница 19: ...KM 225P 60B JKM 230P 60B JKM 235P 60B JKM 240P 60B JKM 245P 60B JKM 250P 60B JKM 255P 60B JKM 260P 60B JKM 265P 60B JKM 200PP 60B JKM 205PP 60B JKM 210PP 60B JKM 215PP 60B JKM 220PP 60B JKM 225PP 60B JKM 230PP 60B JKM 235PP 60B JKM 240PP 60B JKM 245PP 60B JKM 250PP 60B JKM 255PP 60B JKM 260PP 60B JKM 265PP 60B Maximum Power at STC Pmax 200 Wp 205 Wp 210 Wp 215 Wp 220 Wp 225 Wp 230 Wp 235 Wp 240 Wp...

Страница 20: ...Wp 210 Wp 215 Wp 220 Wp 225 Wp 230 Wp 235 Wp 240 Wp 245 Wp 250 Wp 255 Wp 260 Wp 265 Wp 270 Wp 275 Wp 280 Wp Maximum Power Voltage Vmp 28 2 V 28 4 V 28 6 V 28 8 V 29 0 V 29 2 V 29 4 V 29 6 V 29 8 V 30 1 V 30 5 V 30 8 V 30 9 V 31 2 V 31 4 V 31 6 V 31 8 V Maximum Power Current Imp 7 09 A 7 22 A 7 34 A 7 47 A 7 59 A 7 71 A 7 82 A 7 94 A 8 06 A 8 14 A 8 20 A 8 28 A 8 42 A 8 50 A 8 60 A 8 70 A 8 81 A Op...

Страница 21: ...ibility is assumed by Jinko for any infringement of patents or other rights of third parties which may result from use of the PV product NO license is granted by implication or otherwise under any patent or patent rights The information in this manual is based on Jinko s knowledge and experience and is believed to be reliable but such information including product specification without limitations...

Страница 22: ... 20 Note ...

Страница 23: ...100 Tel 86 793 8588188 Fax 86 793 8461152 Jinko solar Import and Export co LTD Xuri District Shangrao Economic Development Zone Jiangxi Province CHINA Postcode 334100 Tel 86 793 8618987 Fax 86 793 8461152 Customer Service cs jinkosolar com Jinko Solar USA 343 Sansome Street Suite 975 San Francisco CA 94104 Tel 415 402 0502 Fax 415 402 0703 us jinkosolar com Jinko Solar Canada Co Ltd Suite 703 100 ...

Страница 24: ... com After sales cs jinkosolar com Global Sales Marketing Center No 1 Jinko Road Shangrao Economic Development Zone Jiangxi Province China 334100 Tel 86 793 858 8188 Fax 86 793 846 1152 Jiangxi Manufacture Base No 58 Yuanxi Road Haining Yuanhua Industrial Park Zhejiang Province China 314416 Tel 86 573 8798 5678 Fax 86 573 8787 1070 Zhejiang Manufacture Base ...

Отзывы: