JH600 Maintenance Manual
Overview
-4-
The connector shall be fully inserted in place.
For a connector with lock, confirm whether the
lock is completely fixed.
Make sure the harness is not falling off
Make sure the plastic jacket of the connector is
securely covering the connector without scaling
off.
12. Before connecting a connector, make sure the
sleeve is not broken and the opening of the
intermediate terminal is not too large.
The joint shall be fully inserted in place.
Make sure the plastic jacket is housing the
terminal completely. The opening of the plastic
jacket shall not face up.
13. The harness fixing strap shall firmly button the
specified position on the frame.
14. The clamp shall reliably bite the wire harness.
In case of a welded clamp, it shall not bite the
wire harness towards the weld mark.
The wire harness shall be clamped at the
position without contacting a rotating part or a
removing element.