Seite | 23
Lifter motor
– gear inspection and encoder cleaning
The lift motor gear, on the right side of the unit, must be inspected every month.
Inspect the lift motor gear for general wear (worn teeth, debris, etc.). Remove any
debris found. If excessive wear is observed, escalate to a technician for repair.
Use a lint-free wipe, damped with DI water, to very gently clean exposed
encoders. Gently rotate the encoder after each wipe to ensure cleaning of the
entire surface.