10
CONSUMPTION - MINIMUM CABLE GAUGE - POWER
TECHNICAL SPECIFICATIONS
40A
60A
70A
120A
150A
200A
600W
900W
1050W
1800W
2250W
3000W
5A
7A
8A
15A
18A
24A
3A
4A
5A
8A
10A
14A
2,5mm2
4mm2
4mm2
4mm2
6mm2
6mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
Model
X-LINE
AC input cable
(up to 10 meters)
DC output cable
(up to 1 meter)
Max power.
Output
40A
60A
70A
120A
150A
200A
Network
220Vac
Network
127Vac
Max.
Consumption
entry
AC input
Consumption with maximum load
Maximum output current
Selectable output voltage
SCI - Intelligent charging system
3-phase slow load system - Customizable
Smart cooler - Smart ventilation system
Precision voltmeter / ammeter
Protections
Dimensions L x A x P (mm)
Weight Kg
X-LINE 40A
90 to 140Vac / 170 to 240Vac (Automatic Bi-volt)
600W
40 Amperes
12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
13,8 / 14,4 cyclic
Elevation /Absorption/ Equalization
Dynamic control by PWM
99% / 96%
Excesso de carga / Curto na saída / Temperatura
259 x 151 x 58
1,420
AC input
Consumption with maximum load
Maximum output current
Selectable output voltage
SCI - Intelligent charging system
3-phase slow load system - Customizable
Smart cooler - Smart ventilation system
Precision voltmeter / ammeter
Protections
Dimensions L x A x P (mm)
Weight Kg
X-LINE 60A
90 to 140Vac / 170 to 240Vac (Automatic Bi-volt)
900W
60 Amperes
12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
13,8 / 14,4 cyclic
Elevation /Absorption/ Equalization
Dynamic control by PWM
99% / 96%
Overload / Short at output / Temperature
259 x 151 x 58
1,440
X-LINE SOURCES AND CHARGERS - INSTRUCTION MANUAL