Measurement and instrumentation 

EVOLIO F15 ± / 0.4 A power supply 

Ref : 
281 002 

ENGLISH

 7 

 

4.2 Sectioning 

It is the power plug that is used as a sectioning device. 

4.3 Symbols used 

   

 :  Caution, refer to accompanying documents. 

 

    

  :  Caution, hot surface. 

5  Care and maintenance 

In case of a malfunction: 

 

Check the mains voltage (230 V) 

 

Check the open circuit voltages, without connecting any load 

If the device still does not work, contact the After Sales Service. 

In all cases, 

do not open the device

. Replacing the mains fuse must be 

done at our workshops. 

Store the original packaging; it can be used to bring the device to our 
workshops for maintenance, if necessary. 
 

6 After-Sales 

Service 

 

This material is under a two year warranty and should be returned to our 
stores in the event of any defects.  
 
For any repairs, adjustments or spare parts, please contact: 
 

JEULIN - TECHNICAL SUPPORT 

Rue Jacques Monod 

BP 1900 

27 019 EVREUX CEDEX FRANCE 

0825 563 563

 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание EVOLIO F15 /0.4 A

Страница 1: ...Mesures et instrumentation Measurement and instrumentation Ref 281 002 Fran ais p 1 English p 5 Version 8010 Alimentation EVOLIO F15 0 4 A EVOLIO F15 0 4 A power supply...

Страница 2: ...der votre circuit lampe moteur diviseur de tension sur les douilles de la sortie s lectionn e Remarque Si le courant d bit sur la sortie utilis e est sup rieur au maximum autoris 0 4 A le courant rest...

Страница 3: ...VA Protection primaire fusible calibr sur C I secondaire lectronique Dimensions 115 x 140 x 80 mm Masse 950 g Garantie 2 ans Cet appareil est conforme La directive Basse Tension 73 23 CEE norme appliq...

Страница 4: ...ne fonctionne toujours pas contacter le Service Apr s Vente Dans tous les cas ne pas ouvrir l appareil Le changement du fusible secteur doit tre fait dans nos ateliers Conserver l emballage d origine...

Страница 5: ...Mesures et instrumentation Alimentation EVOLIO F15 0 4 A Ref 281 002 FRAN AIS 4 NOTES...

Страница 6: ...upply to the 230 V mains supply Toggle the master switch so that the power on indicator lamp comes on Connect your circuit lamp motor voltage divider etc to the selected output sockets Notes If the cu...

Страница 7: ...each output Stabilisation 1 Residual ripple Less than 10 mV Power supply 230 V 10 50 60 Hz Power consumed from the mains 30 VA Protection Primary fuse calibrated on I C Secondary electronic Dimensions...

Страница 8: ...ing any load If the device still does not work contact the After Sales Service In all cases do not open the device Replacing the mains fuse must be done at our workshops Store the original packaging i...

Страница 9: ...Measurement and instrumentation EVOLIO F15 0 4 A power supply Ref 281 002 ENGLISH 8 NOTES...

Страница 10: ......

Отзывы: