Jetter AG
Technical specifications | 5
JXM-HMI User Manual
10 / 22
5 Technical specifications
5.1 Dimensions
6
2
.9
28.5
33.9
21.3
80
4
4
.5
8
.5
3.
2
Ø
Fig. 3:
Dimensions (in mm)
5.2 Environmental conditions
Category
Description
Standards
Operating temperature
-30 … +85 °C
Storage temperature
-30 … +85 °C
Relative humidity
5 ... 95 %
Installation location
The device must be installed in
the driver's cab.
Degree of protection
IP42 with mating connector
plugged in
ISO 20653:2013
Tab. 2:
Environmental conditions
Climatic tests
Category
Standards
Functional class
Temperature, cyclically
DIN EN 60068-2-14
(2 cycles for function test)
A
DIN EN 60068-2-14
(5 cycles for material test)
C
Humidity/temperature,
cyclically
DIN EN 60068-2-38
(-10 °C ... 55 °C)
A
Tab. 3:
Climatic tests
5.3 Mechanical specifications
Category
Description
Standards
Vibration
ISO 16750-3
Floating frequency
10 … 150 Hz
Period
6 h
Shock resistance
ISO 16750-3
Type of shock
Half-sine wave
Intensity and duration
50 g (500 m/s²) for 18 ms
Number and direction
10 shocks in all 6 directions
Height of fall
ISO 16750-3