Jetter AG
Programming | 7
JX3-BN-EC User Manual
70 / 92
Index
Sub-
in-
dex
Description/
Name
Type
Type
of ac-
cess
0x6000
:0x07 DI 3
BOOL
RO
:0x08 DI 4
BOOL
RO
:0x09 DI 5
BOOL
RO
:0x0A DI 6
BOOL
RO
:0x0B DI 7
BOOL
RO
:0x0C DI 8
BOOL
RO
0x8000
Parameter Module:JX3-MIX1
:0x00 SubIndex 000
USINT
RO
:0x01 Modulestate..State
UDINT
RW
:0x02 Outputs..All Outputs
UDINT
RW
:0x03 Digital Outputs..All Outputs
UDINT
RW
:0x04 Digital Outputs..Output 1
BOOL
RW
:0x05 Digital Outputs..Output 2
BOOL
RW
:0x06 Digital Outputs..Output 3
BOOL
RW
:0x07 Digital Outputs..Output 4
BOOL
RW
:0x08 Digital Outputs..Output 5
BOOL
RW
:0x09 Digital Outputs..Output 6
BOOL
RW
:0x0A Digital Outputs..Output 7
BOOL
RW
:0x0B Digital Outputs..Output 8
BOOL
RW
:0x0C analog input 1..command
UDINT
RW
:0x0D analog input 1..analog input 1: averaging
UDINT
RW
:0x0E analog input 2..command
UDINT
RW
:0x0F analog input 2..analog input 2: averaging
UDINT
RW
:0x10 analog input 3..command
UDINT
RW
:0x11 analog input 3..analog input 3: averaging
UDINT
RW
:0x12 analog out 1..output value 0 - 4095
UDINT
RW
:0x13 counter A..counter value
UDINT
RW
:0x14 counter A..command register counter A
UDINT
RW
:0x15 counter B..counter value
UDINT
RW
:0x16 counter B..command register counter B
UDINT
RW
:0x17 stepper motor..command
UDINT
RW
:0x18 stepper motor..position setpoint
UDINT
RW
:0x19 stepper motor..position actual value
UDINT
RW
:0x1A oscilloscope..command
UDINT
RW
:0x1B oscilloscope..parameter index
UDINT
RW
:0x1C oscilloscope..parameter
UDINT
RW
:0x1D oscilloscope..data index
UDINT
RW
:0x1E Diagnostics..command for module
UDINT
RW
0xA000
Status Module:JX3-MIX1
:0x00 SubIndex 000
USINT
RO
:0x01 Inputs..All Inputs
UDINT
RO
:0x02 Digital Inputs..All Inputs
UDINT
RO
:0x03 Digital Inputs..Input 1
BOOL
RO
:0x04 Digital Inputs..Input 2
BOOL
RO
:0x05 Digital Inputs..Input 3
BOOL
RO
:0x06 Digital Inputs..Input 4
BOOL
RO