Jetter AG
Register overview - Multi-purpose inputs and outputs | 9
JVM-104-O09 User Manual
53 / 62
Multi-purpose out-
put PA2
Register
Description
601040000
Status PA2
601040001
Command PA2
601040002
PWM pulse control factor (duty cycle) in steps of 0.1 %
601040004
Digital value at the output
601040005
Measured current PA2 in mA
601040006
PWM frequency in Hz
601040007
Adjustable overcurrent limit in mA
601040010
Dither feature - The xth pulse is overlaid
601040011
Dither function - Width of the dither signal in ±0.1 %
Multi-purpose out-
put PA3
Register
Description
601050000
Status PA3
601050001
Command PA3
601050002
PWM pulse control factor (duty cycle) in steps of 0.1 %
601050004
Digital value at the output
601050005
Measured current PA3 in mA
601050006
PWM frequency in Hz
601050007
Adjustable overcurrent limit in mA
601050010
Dither feature - The xth pulse is overlaid
601050011
Dither function - Width of the dither signal in ±0.1 %
Multi-purpose out-
put PA4
Register
Description
601060000
Status PA4
601060001
Command PA4
601060002
PWM pulse control factor (duty cycle) in steps of 0.1 %
601060004
Digital value at the output
601060005
Measured current PA4 in mA
601060006
PWM frequency in Hz
601060007
Adjustable overcurrent limit in mA
601060010
Dither feature - The xth pulse is overlaid
601060011
Dither function - Width of the dither signal in ±0.1 %
9.2 Multi-purpose input MFQEx
Placeholders are used for these register numbers. The following rule applies:
x = 1 for multi-purpose output 1 (as of 601010000)
x = 2 for multi-purpose output 2 (as of 601020000)
Register
Description
6010x0000
Status
Bit 0
Overcurrent
1 =
In current measurement mode triggered by a current >
2500 mA.
Bit 7
Overtemperature
1 =
Overtemperature is present
Bit 14
Multi-purpose input MFQEx is ...
0 =
enabled
1 =
disabled