9 Register overview - Multi-purpose inputs and
outputs
This register overview describes the registers of the multipurpose inputs and out-
puts of the JVM-104-O09.
9.1 General overview - Registers
Internal I/O board
Register
Description
601000000
Hardware identification
601000001
Hardware revision (displayed in IP format)
601000003
Software version (displayed in IP format)
601000013
Complete the number of CRC errors
601000014
Number of firmware errors since the last restart
601000015
CPU temperature in 1 °C
601000016
Voltage supply logic circuit in mV
601000020
Error code of the device
601000021
Software module being the source of the error
Multi-purpose input
MFQE1
Register
Description
601010000
Status MFQE1
601010001
Command MFQE1
601010002
Analog value in µA/mV
601010003
Frequency [gate time]/period [μs]/count value [increments]
601010004
Digital value at the input
601010005
Gate time in ms within frequency metering
Multi-purpose input
MFQE2
Register
Description
601020000
Status MFQE2
601020001
Command MFQE2
601020002
Analog value in µA/mV
601020003
Frequency [gate time]/period [μs]/count value [increments]
601020004
Digital value at the input
601020005
Gate time in ms within frequency metering
Multi-purpose out-
put PA1
Register
Description
601030000
Status PA1
601030001
Command PA1
601030002
PWM pulse control factor (duty cycle) in steps of 0.1 %
601030004
Digital value at the output
601030005
Measured current PA1 in mA
601030006
PWM frequency in Hz
601030007
Adjustable overcurrent limit in mA
601030010
Dither feature - The xth pulse is overlaid
601030011
Dither function - Width of the dither signal in ±0.1 %