Programming | 7
JVM-104-O09 User Manual
32 / 62
Var
Ignition: Int
At
%VL
361100
;
End_Var;
Task
Ign
Autorun
Loop
When
Ignition
Continue;
Delay(
3000
);
Shutdown(
False
);
End_Loop;
End_Task;
INFO
For more information on this subject, refer to JetSym online help.
7.6 Multi-purpose inputs
Introduction
The special registers of the HMI have got the functions listed below:
■
Programming multi-purpose inputs
■
Programming multi-purpose outputs
■
Retrieving the hardware and software version for I/O functions
Placeholder x
Placeholder x is for clearer representation. The table below shows how place-
holders are used to address individual inputs. Throughout this chapter the follow-
ing rules apply:
Placeholder
Value
Description
x
1
Multi-purpose input MFQE1
2
Multi-purpose input MFQE2
Tab. 32:
Description of the placeholder x
Example
x = 2 for multi-purpose output 2. You can read the overtemperature from R
601020000.7.
Registers - Over-
view
Each of the multi-purpose inputs MFQE1 and MFQE2 has got the following regis-
ters:
Register
Description
6010x0000
Status (bit-coded)
6010x0001
Command (bit-coded)
6010x0002
Analog value in µA/mV
6010x0003
Frequency [gate time]/period [μs]/count value [in-
crements]
6010x0004
Digital value of the active-high input
6010x0005
Gate time in ms within frequency metering
Tab. 33:
Register overview - Multi-purpose inputs