6 Installation Guide
JetWeb
42
Jetter AG
6.8
SSI Encoder
6.8.1
Description of Connections
15-Pin Female SUB-D Connector X61
SSI Encoder
View
Pin
Signal
Comment
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
GND
Do not connect
Do not connect
DATA +
DATA -
Do not connect
Do not connect
CLOCK -
CLOCK +
DC 5 V (-5%)
Do not connect
Do not connect
Do not connect
Do not connect
Do not connect
Reference potential
Data line
Inverted data line
Inverted clockline
Clockline
Power supply for encoders with
operating voltage DC 5 V, short-
circuit proof up to 100 mA
JX2-CNT1
Jetter
REF
K1
K2
K0
S
S 0V
STR
0V
REF
INPUT
X21
X61
ENCODER
X
1
8
9
15
Important!
Reversal of CLOCK signals produces invalid position values.
If DATA + and DATA - are reversed, the JX2-CNT1 module reads out the first
complement of the binary or Gray-coded encoder value.
In the case of Gray-
coding this error has fatal effects: The module fails to produce continuous
position values which, therefore, cannot be used.
In the case of binary coding
the counting direction is reversed.
Содержание JetWeb JX2-CNT1
Страница 10: ...Table of Contents JetWeb 10 Jetter AG ...
Страница 18: ...1 Safety Instructions JetWeb 18 Jetter AG ...
Страница 26: ...JetWeb 26 Jetter AG ...
Страница 58: ...8 2 Firmware Version JetWeb 58 Jetter AG ...
Страница 60: ...JetWeb 60 Jetter AG ...
Страница 63: ...JX2 CNT1 10 Dual Channel Counter Jetter AG 63 Fig 13 Signal waveform for single channel counting ...
Страница 74: ...11 1 Reading in SSI data JetWeb 74 Jetter AG Fig 18 Examples Reading in Different SSI Formats ...
Страница 82: ...12 1 Sample Program JetWeb 80 Jetter AG ...
Страница 90: ...13 2 Mode 2 Operation along with JM 2xx JetWeb 94 Jetter AG ...
Страница 91: ...JX2 CNT1 Appendices Jetter AG 95 Appendix ...
Страница 92: ...Appendices JetWeb 96 Jetter AG ...
Страница 95: ...JX2 CNT1 Appendices Jetter AG 99 ...
Страница 99: ...JX2 CNT1 Appendices Jetter AG 103 ...