Jets Jade Скачать руководство пользователя страница 6

Jets™ Jade Floor Toilet 

Tel. +47 70 03 91 00

www.jetsgroup.com

Product No. TO661PO

Rev 2017-08-29 14:46

6

11

Completed.

12

Function Check to be Completed Prior to Use

1. Check that the inside of the toilet bowl is empty of packaging 

material, etc. 

2. Ensure that the discharge valve has been securely connected to 

the outlet pipe.

3. Check that the water supply is connected and water pressure is 

adequate.

4. Turn on the water supply.
5. Press the release mechanism to activate the valve.
6. Check that the bowl fills with water.
7. Check that sufficient vacuum is created when activating the 

release mechanism to release the contents of the bowl. 

8. Check that the water level in the bowl is restored.
9. Check that water is dispersed on the bowl surface by the 

flushing mechanism.

10. Check that there are no water or air leaks.

Service and Maintenance

Out of Use

The following procedures are to be followed if a toilet is to be out of use over a longer period of time (i.e. for cabins and recreational houses).

1. Close the water supply to the toilet.
2. Activate the release button to run a flush cycle, emptying the toilet of water.
3. Close the toilet seat cover.
4. CAUTION: This toilet is not intended for use in temperatures below freezing without appropriate antifreeze measures being taken. For 

locations where freezing may occur, certain protection measures must be taken. For further information contact Jets Vacuum AS or your 
nearest supplier for a copy of technical information regarding freezing protection measures.

5. CAUTION: Never use automotive antifreeze (ethylene glycol) in the toilet system.
6. Turn off the power.

NOTE: Failure to adequately protect the toilet system from damages may result in void of your warranty coverage. 

NOTE: Jets Vacuum AS reserves the right to deny any warranty claim submitted if the claim is caused by freezing damage.  

Cleaning Instructions

1. Mild soap or biological cleaners are recommended for cleaning the toilet. See Jets™ product range for suitable cleaning solutions.
2. Do not use cleaners that create foam.
3. The toilet is to be cleaned regularly to maintain hygiene. Also note that maintaining water in the toilet bowl will prevent odors.
4. Do not use drain cleaner, bleach or other caustic cleaners. These types of cleaners can damage components in the toilet system and damage 

the seat and cover hinges.

5. For mineral scale buildup, we recommend use of Jets Vacuum AS biological descale products. Contact your Jets Vacuum AS supplier for 

information.

Spare Parts and Accessories

Available spare parts are indicated in the component list for the toilet. Spare parts and accessories can be ordered via your local Jets Vacuum AS 
supplier. For multi-toilet installations, a complete recommendation for spare parts is available. Contact your Jets Vacuum AS supplier for details. 

Service and Maintenance

Jets Vacuum AS provides all customers with 24 hour worldwide technical assistance. For urgent  matters please contact Jets Vacuum AS service 
department directly at +47 70039100. For other matters, please contact your nearest Jets Vacuum AS supplier. 

Содержание Jade

Страница 1: ...ge Valve Outlet Outside diameter Ø 50 mm Water Connection male BSP Generic Material Porcelain Net Weight N A Coating Vitreous China Operating Data Flushing Time 5 seconds Discharge Time 2 seconds Water Pressure 2 7 bar Operating Vacuum Recommended 30 55 Vacuum Air Consumption Approx 48 liters at 50 Vacuum Water Consumption 1 liter s 3 bar Temperature Range Minimum 1 C to Maximum 60 C unless frost ...

Страница 2: ...m C If H is 40mm 115mm D If H is 40mm 160mm E Release mechanism normal height 670mm F 830mm G Release mechanism public toilet height 950mm H see note 40mm I If H is 40mm 155mm J 65mm Note If the toilet is placed further than 40mm away from the back wall the values of C D F and I will change H Should be a minimum of 40mm and a maximum of 70mm ...

Страница 3: ...entified lifting points or as instructed in the current IOM Note Lifting devices eyebolts slings spreaders etc must be rated selected and used for the entire load being lifted 1 4 Caution Safety equipment PPE necessary for the prevention of accidents at the installation and operating site must be provided in accordance with local regulations 1 5 Personal Protective Equipment Goggles Wear safety gl...

Страница 4: ...onto the wall if mounting requires that the water barrier be compromised Check requirements according to local codes and standards before beginning any installation work Pre Installation Considerations It is recommended that items such as wall mounted release buttons drainage and piping etc is installed prior to installation of the toilet Connection with Mains Water The connection required is a 1 ...

Страница 5: ...3 2 Install the toilet valve and the spring as per the products installation instructions found in the products data sheet 3 If using Installation Alternative 2 affix the cap A from the Pipe Cover to the wall B will be installed later 4 Move the toilet close to the wall Connect the ball valve from the toilet valve to the water main Note Do not over tighten 5 Connect the release button mechanism to...

Страница 6: ...or a copy of technical information regarding freezing protection measures 5 CAUTION Never use automotive antifreeze ethylene glycol in the toilet system 6 Turn off the power NOTE Failure to adequately protect the toilet system from damages may result in void of your warranty coverage NOTE Jets Vacuum AS reserves the right to deny any warranty claim submitted if the claim is caused by freezing dama...

Страница 7: ...quipment and take measures to prevent future damage to the system Note that frost and or freezing may damage sanitary systems if precautions have not been taken Contact your nearest Jets supplier for information on Jets range of frost protection products for installations in cold climate locations Troubleshooting Jets Vacuum AS provides the following troubleshooting information to assist in resolv...

Страница 8: ...8 Backflow in the installation Check the pipes have been correctly installed The Non return Valve on the discharge line if installed is malfunctioning Clean the Non return Valve If connected to a tank the tank could be full or the air overflow blocked Check that the air overflow is open Empty the tank ...

Отзывы: