Important Health and Safety Information

Installation, operation and maintenance must be carried out in strict accordance with this guide and with all applicable regulations. For your own 
protection and the protection of others, it is necessary to familiarize yourself with, and always follow, the contained safety and environmental 
precautions for our products.

This manual is an integral part of the product/delivery. Always keep it in a safe place for future reference. It is entirely the owner’s responsibility to 
ensure that all safety and environmental measures, in accordance with local, state and federal laws are followed. Jets Vacuum AS assumes no 
responsibility for equipment damage, personal injury or death and/or delays that result from a lack of respect for the instructions for installation 
and/or use as stated in this documentation. Disregarding these instructions may invalidate all warranties.

Safety information references are in accordance with Jets Vacuum AS documentation system. If you do not understand the warnings, stop work 
immediately and contact Jets Vacuum AS (citing the safety reference number) for further clarification. 

For further information about the included warnings or any other safety concerns please contact Jets Vacuum AS.

Safety Warning Symbols

General information to all users.

Symbol denotes required personal protective equipment is required.

Symbol denotes required personal protective equipment is required.

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result 
in death or serious injury or equipment damage.

CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in 
minor or moderate injury or equipment damage.

Important Health and Safety Warnings

1.1 Warning

Jets Vacuum AS recommend qualified person(s) in accordance with all applicable 
codes and standards to carry out all installation work, electrical wiring, plumbing and 
operate this product. Equipment damage, injury to personnel or death could result 
from improper installation/use. 

1.2 Warning

Be thoroughly familiar with the controls and the proper use of the equipment prior 
to installing, starting or using the equipment. Know the equipment application, 
limitations and potential hazards.

1.3 Warning

Failure to properly lift and support equipment can result in serious physical injury and/
or equipment damage. Lift equipment only at specifically identified lifting points or as 
instructed in the current IOM. Note: Lifting devices (eyebolts, slings, spreaders, etc.) 
must be rated, selected, and used for the entire load being lifted.

1.4 Caution

Safety equipment (PPE) necessary for the prevention of accidents at the 
installation and operating site must be provided in accordance with local 
regulations.

1.5 Personal Protective Equipment - Goggles

Wear safety glasses with side shields at all times when working with equipment.

1.6 Warning

Keep work area clean, uncluttered and ensure adequate lighting.  

1.7 Warning

Keep other persons at a safe distance from work area.

1.9 Personal Protective Equipment - Gloves

Wear suitable protective gloves at all times when working with equipment.

2.14 Warning

The equipment safety is guaranteed only if used in compliance with the instructions 
provided. Do not exceed the limits provided.

12.5 Notice

Use this equipment only in the manner intended by Jets Vacuum AS. If you have 
questions after reading these instructions contact Jets Vacuum AS directly.

Delivery, Receipt of Goods and Transportation

Goods to be protected against shock, dust, humidity and moisture. Suitable adequately dimensioned transporting equipment is to be used. Note 
that the equipment may contain components that are easily damaged as a result of inappropriate handling. Jets Vacuum AS is not responsible for 
or liable for delivery delays resulting from occurrences outside of Jets Vacuum AS' immediate control. On receipt of goods, check for visual 
damage. Any damage detected after dispatch should be reported immediately to Jets Vacuum AS. Damages and/or discrepancies must be 
reported in writing no later than eight (8) days after receipt of goods. Commissioning must be postponed until the equipment has been inspected. 
Do not dispose of damaged items. Your direct supplier will advise you of the procedure to follow.

Storage

Unless otherwise specified, goods are to be stored in a dry environment between -30°C and +40°C prior to installation. The storage location must 
be dust free, low humidity (≤95%) and be free from moisture. Keep clear of foreign objects.

Installation to End Use

Site to be a dry environment b0°C and +60°C. Use in environments below 0°C requires use of antifreeze in liquids. The site location is to 
be low vibration Vrms ˂0.2 mm/s) with vibration resistance to acceleration up to 0.7g. The site is to be dust free and protected from grinding and 
welding. Goods are to be stored as per the instructions for delivery, storage and transport. A visual inspection is to carried out on receipt of goods
as well as at the time of installation to ensure that storage and transport conditions after receipt have not compromised the quality of the product/s. 

Содержание Jade

Страница 1: ...ge Valve Outlet Outside diameter Ø 50 mm Water Connection male BSP Generic Material Porcelain Net Weight N A Coating Vitreous China Operating Data Flushing Time 5 seconds Discharge Time 2 seconds Water Pressure 2 7 bar Operating Vacuum Recommended 30 55 Vacuum Air Consumption Approx 48 liters at 50 Vacuum Water Consumption 1 liter s 3 bar Temperature Range Minimum 1 C to Maximum 60 C unless frost ...

Страница 2: ...m C If H is 40mm 115mm D If H is 40mm 160mm E Release mechanism normal height 670mm F 830mm G Release mechanism public toilet height 950mm H see note 40mm I If H is 40mm 155mm J 65mm Note If the toilet is placed further than 40mm away from the back wall the values of C D F and I will change H Should be a minimum of 40mm and a maximum of 70mm ...

Страница 3: ...entified lifting points or as instructed in the current IOM Note Lifting devices eyebolts slings spreaders etc must be rated selected and used for the entire load being lifted 1 4 Caution Safety equipment PPE necessary for the prevention of accidents at the installation and operating site must be provided in accordance with local regulations 1 5 Personal Protective Equipment Goggles Wear safety gl...

Страница 4: ...onto the wall if mounting requires that the water barrier be compromised Check requirements according to local codes and standards before beginning any installation work Pre Installation Considerations It is recommended that items such as wall mounted release buttons drainage and piping etc is installed prior to installation of the toilet Connection with Mains Water The connection required is a 1 ...

Страница 5: ...3 2 Install the toilet valve and the spring as per the products installation instructions found in the products data sheet 3 If using Installation Alternative 2 affix the cap A from the Pipe Cover to the wall B will be installed later 4 Move the toilet close to the wall Connect the ball valve from the toilet valve to the water main Note Do not over tighten 5 Connect the release button mechanism to...

Страница 6: ...or a copy of technical information regarding freezing protection measures 5 CAUTION Never use automotive antifreeze ethylene glycol in the toilet system 6 Turn off the power NOTE Failure to adequately protect the toilet system from damages may result in void of your warranty coverage NOTE Jets Vacuum AS reserves the right to deny any warranty claim submitted if the claim is caused by freezing dama...

Страница 7: ...quipment and take measures to prevent future damage to the system Note that frost and or freezing may damage sanitary systems if precautions have not been taken Contact your nearest Jets supplier for information on Jets range of frost protection products for installations in cold climate locations Troubleshooting Jets Vacuum AS provides the following troubleshooting information to assist in resolv...

Страница 8: ...8 Backflow in the installation Check the pipes have been correctly installed The Non return Valve on the discharge line if installed is malfunctioning Clean the Non return Valve If connected to a tank the tank could be full or the air overflow blocked Check that the air overflow is open Empty the tank ...