Pre-Installation

Standards and Regulations

To install a Jets™ product, it is first required that the room be prepared according to all local, state and federal standards and requirements. 
Industry specific standards must also be met. Considerations that must be made include but are not limited to:

● Appropriate dimensioned drain pipes.
● Water barrier or membrane.

Installations required to meet AS/NZS 3500 series of Standards must adhere to the following: 
(Ref: Australian and New Zealand Standards: AS/NZS 3500  - AS3500 Part 2 Sanitary Plumbing and Drainage )

● Discharge by a vacuum toilet system shall be regarded as "pumped discharge" and shall be pumped according to AS/NZ3500 "Pumped 

Discharge" requirements.

● Installation of the vacuum toilet system shall be according to the requirements of AS/NZ 3500.2 Sanitary Plumbing and Drainage.

Tools and Training

No special tools other than those used in standard plumbing installations are required. No special training is required to install this product. 

Water Barrier

Note that in some countries, and as per the majority of standards and regulations, it is prohibited to mount toilets directly onto the wall if mounting 
requires that the water barrier be compromised. Check requirements according to local codes and standards before beginning any installation 
work.

Pre-Installation Considerations

It is recommended that items such as wall mounted release buttons, drainage and piping etc. is installed prior to installation of the toilet.

Connection with Mains Water

The connection required is  a 1/2" BSP standard connection. The water pressure must be a minimum of 2 bar and must not exceed 7 bar. 

Connection without Mains Water

The toilet may be connected to a local water supply such as a container, tank or can. A water pump must be used. Refer to the individual product 
data sheet for further instructions regarding connections.

Backflow Prevention

Backflow Prevention 
Please refer to local, state, federal and/or international regulations regarding the extent of backflow requirements for your specific installation.

For installations whereby the valve is to be connected to a drinking water supply, it is recommended that the water connection is installed with a 
backflow prevention device.  Please refer to the local regulations in your area.  If backflow prevention is required in Australia, refer to AS/NZ3500.1 
Backflow Prevention.

Toilet Connections

Installation may vary depending on plumbing arrangements. Note that the following methods are available for the toilet type.

Installation Alternative 1

Installation Alternative 2

Содержание Jade

Страница 1: ...ge Valve Outlet Outside diameter Ø 50 mm Water Connection male BSP Generic Material Porcelain Net Weight N A Coating Vitreous China Operating Data Flushing Time 5 seconds Discharge Time 2 seconds Water Pressure 2 7 bar Operating Vacuum Recommended 30 55 Vacuum Air Consumption Approx 48 liters at 50 Vacuum Water Consumption 1 liter s 3 bar Temperature Range Minimum 1 C to Maximum 60 C unless frost ...

Страница 2: ...m C If H is 40mm 115mm D If H is 40mm 160mm E Release mechanism normal height 670mm F 830mm G Release mechanism public toilet height 950mm H see note 40mm I If H is 40mm 155mm J 65mm Note If the toilet is placed further than 40mm away from the back wall the values of C D F and I will change H Should be a minimum of 40mm and a maximum of 70mm ...

Страница 3: ...entified lifting points or as instructed in the current IOM Note Lifting devices eyebolts slings spreaders etc must be rated selected and used for the entire load being lifted 1 4 Caution Safety equipment PPE necessary for the prevention of accidents at the installation and operating site must be provided in accordance with local regulations 1 5 Personal Protective Equipment Goggles Wear safety gl...

Страница 4: ...onto the wall if mounting requires that the water barrier be compromised Check requirements according to local codes and standards before beginning any installation work Pre Installation Considerations It is recommended that items such as wall mounted release buttons drainage and piping etc is installed prior to installation of the toilet Connection with Mains Water The connection required is a 1 ...

Страница 5: ...3 2 Install the toilet valve and the spring as per the products installation instructions found in the products data sheet 3 If using Installation Alternative 2 affix the cap A from the Pipe Cover to the wall B will be installed later 4 Move the toilet close to the wall Connect the ball valve from the toilet valve to the water main Note Do not over tighten 5 Connect the release button mechanism to...

Страница 6: ...or a copy of technical information regarding freezing protection measures 5 CAUTION Never use automotive antifreeze ethylene glycol in the toilet system 6 Turn off the power NOTE Failure to adequately protect the toilet system from damages may result in void of your warranty coverage NOTE Jets Vacuum AS reserves the right to deny any warranty claim submitted if the claim is caused by freezing dama...

Страница 7: ...quipment and take measures to prevent future damage to the system Note that frost and or freezing may damage sanitary systems if precautions have not been taken Contact your nearest Jets supplier for information on Jets range of frost protection products for installations in cold climate locations Troubleshooting Jets Vacuum AS provides the following troubleshooting information to assist in resolv...

Страница 8: ...8 Backflow in the installation Check the pipes have been correctly installed The Non return Valve on the discharge line if installed is malfunctioning Clean the Non return Valve If connected to a tank the tank could be full or the air overflow blocked Check that the air overflow is open Empty the tank ...

Отзывы: