Page 19
Bullfrog Spas Owner’s Manual
Diagnostic Messages
Meaning
No message on display.
Power has been cut off to the spa.
“Overheat” - The spa has shut down. One
of the sensors has detected that the spa
water is 110°F (approximately 43.3°C).
“Overheat” - The spa has shut down. One
of the sensors has detected 118°F
(approximately 47.8°C) at the heater.
“Ice” - Potential freeze condition
detected.
Spa is shut down. The sensor that is
plugged into the Sensor “A” jack is not
working.
Spa is shut down. The sensor that is
plugged into the Sensor “B” jack is not
working.
Action Required
The control panel will be disabled until power returns.
Spa settings are preserved until the next power-up.
DO NOT ENTER THE WATER.
Remove the spa cover
and allow water to cool. At 107°F (approximately 41.7°
C), the spa should automatically reset. If spa does not
reset, shut off the power to the spa and call your
dealer or service organization.
DO NOT ENTER THE WATER.
Remove the spa cover
and allow water to cool. Once the heater has cooled,
reset by pushing any button. If spa does not reset,
shut off the power to the spa and call your dealer or
service organization.
No action required. The pumps and the blower will
automatically activate
regardless of spa status.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
Message
There are two filter cycles per day. The start/end times of each cycle are programmable. To program, set time as
instructed above, then press “Mode/Prog” to advance to the next setting (or to exit after the last setting). The de-
fault filter cycles are as follows: The first filter cycle is automatically activated at 8:00 AM and operates the pump
until 10:00 AM. The filter 1 indicator icon will
light when filter 1 is running. The second filter cycle is automatically activated at 8:00 PM and operates the pump
until 10:00 PM. The filter 2 indicator icon will light when filter 2 is running.
Clean-up Cycle
(optional)
When the pump is turned on by a button press, a clean-up cycle begins 30 minutes after the pump is turned off
or times out. The pump and the ozone generator** will run for one hour.
**Ozone
(optional)
On most systems, the ozone generator (if installed) runs during filter cycles (except when pump 1 is operating at
high speed and during clean-up cycles.
Freeze Protection
If the temperature sensors detect a drop to 44°F (approximately 6.7°C) within the heater, then the pump auto-
matically activates to provide freeze protection. The equipment stays on until 4 minutes after the sensors detect
that the spa temperature has risen to 45°F
(approximately 7.2°C) or higher. In colder climates, an optional additional freeze sensor may be added to protect
against freeze conditions that may not be sensed by the standard sensors. Aux freeze sensor protection acts
similarly except with the temperature thresholds determined by the switch and without a 4-minute delay in turn-
off. See your dealer for details.
Locking the Panel
Press “Time” “Jets 1” then “Warmer” within 3 seconds. When locked, the PL indicator light will light. All buttons are
frozen except the “Time” button. To unlock the panel, press “Time” “Jets 1” then “Cooler.”
Locking the Set Temperature
Press “Warmer” or “Cooler” then “Time,” “Jets 1,” and “Warmer” within 3 seconds to activate the lock. The TL indi-
cator light will light when the set temperature is locked. To unlock the set temperature, press “Warmer” or
“Cooler” then “Time,” “Jets 1” and “Cooler.”