Installation and operation of the Mynx
INSTALLATION & OPERATING INSTRUCTIONS
6
INSTALLATION AND
OPERATING INSTRUCTIONS: Mynx
provided to prevent the wooden beams
from overheating.
It is recommended that all joints in the
flue pipe, should be secured using self-
drilling screws, and sealed using heat
resistant silicone. It is normally not
necessary to secure a single joint that is
visible from the inside of the room. Care
must be taken to ensure that the integrity
of the flue installation is not compromised.
iv) Roof Cavity
It is important that all combustible
materials in the ceiling cavity be protected
from the heat radiated by the flue pipe.
It is recommended that the complete flue
run in the ceiling cavity be insulated, using
ceramic wool.
A gap of at least 150mm must be left
between the flue pipe and any wooden
beams. Should the gap be less than 150mm,
and then added insulation must be