computer radio control system
EN
Other parameters displayed in this menu are:
•
EX Parameter. Here you can select your sensor and its
parameter which will act as a source for the Vario system. The Climb
Rate is predefined by default (if the MVARIO EX is detected) but you
are free to choose one of the other sensors and their parameters (for
example: an RPM probe to indicate high revolutions).
•
Dead Zone (negative and positive). This field sets an area
around the centre of the range with no acoustic signal. Values are
relative to the center.
•
Range (minimum, center and maximum). Here you can define
the full range of the sensor which will be indicated by the Vario
system.
The actual value of the sensor and its appropriate Vario output are
indicated at the bottom of the screen.
Centre of range
Negative dead zone
Positive dead zone
Silence
Permanent sound
Beeping...
Minimum
Maximum
9.4.4
Voice Output
This powerful function makes it easier for all modellers who need to
know their actual telemetry values often but they don't want to (or
cannot) look at the display because it may be inconvenient or
dangerous.
Voice output for a timer
The first menu row represents settings for the voice output of a timer.
The actual status of a single timer can be expressed by a synthesized
voice. If you select the desired timer and a switch, every time the
switch is activated, the actual time is stated aloud.
If the timer type equals “Laps” type, another menu row equipped
with checkbox appears below. In this row, “Report previous lap”
allows you to determine whether you want to hear the time of a
current lap which is already running, or hear the time of the previous
lap which has ended recently.
Voice output for telemetry
There are two independent queues dedicated to output telemetry
values. The first queue repeats its message every x seconds (number
of seconds elapsed is displayed over the F(1) button). You can also
assign a switch to enable or disable the repeating of the countdown.
Every time this switch is activated, the appropriate variables are
reported by voice and then the countdown starts a new round until a
timeout is reached.
The second voice queue specifies which variables are reported only
once, after a single press of a switch. You can select a Trigger switch
and a list of variables that are reported when the switch is activated.
4.
4.
73
Содержание Duplex DC-16
Страница 1: ...computer radio control system DE DC 16 DE FW 1 06...
Страница 6: ...computer radio control system DE 5...
Страница 7: ...computer radio control system DE 6...
Страница 8: ...computer radio control system DE 7...
Страница 9: ...computer radio control system DE 8...
Страница 10: ...computer radio control system DE 9...
Страница 11: ...computer radio control system DE 10...
Страница 115: ...computer radio control system DE 114...
Страница 116: ...computer radio control system DE 115...
Страница 117: ...computer radio control system DE JETI model s r o Lomen 1530 742 58 P bor www jetimodel de...
Страница 118: ...computer radio control system EN DC 16 EN FW 1 06...
Страница 123: ...computer radio control system EN 5...
Страница 221: ...computer radio control system EN 5 5 103...
Страница 222: ...computer radio control system EN JETI model s r o Lomen 1530 742 58 P bor www jetimodel com...