Shutdown 

To stop operation and shut down the machine, turn the 
knob (3) on the main switch until it reaches position a. 

 

 

 

 
 
Safety thermostat manual reset 

A temperature-limit thermostat will stop power feeding in 
case  of  overheating.  If  the  thermostat  releases, 
disconnect fan electricity, wait until the fan has cooled and 
fix the problem causing overheating. 
To  reset  the  temperature-limit  thermostat,  remove  the 
cover and press the switch (2). 

 

Maintenance 
Warning 

before 

carrying 

out 

any 

maintenance 

operation you must: 

•  stop the heater; 
•  turn  off  the  disconnecting  switch  on  the 

electric switchboard; 

•  wait until the heater has cooled down.  

 

 
 
 
 
 

 
Cleaning

 

For the heater to operate efficiently, cleaning operations 

must be carried out regularly. Dust and dirt may result in 
overheating and fire. 

 

Disposal 

At the end of its useful life, you have to scrap and dispose 
of this product by taking it to a local differentiated waste 
collection center in conformity to law. 
Before scrapping the unit, check the machine data plate: 
if it bears the symbol, it means that disposal is regulated 
by  the  Italian  legislative  decree  151  of  25/07/2005  and 
directive  2002/96/ec  on  waste  electrical  and  electronic 
equipment (waee). 
The  user  must  inquire  about  the  local  electrical  and 
electronic  waste  collection  system  and  follow  its 
instructions. 
Illegal disposal of this product with normal domestic waste 
can  seriously  harm  the  environment  and  health  and  is 
subject to administrative penalties. 

 

 
 
 
 
 
 
 
OBSERVED FAULTS, POSSIBLE CAUSES AND 
REMEDIES 

 
 

 

 
 
 
 

 
 
 
 
 
 
 
 
 

 
 
 

OBSERVED FAULT 

CAUSE 

REMEDY 

• The fan doesn’t start 

• No electrical current 

• Check mains, it should be 
• Check proper positioning and 
functioning of switch 

• Winding of motor burnt or interrupted  • Replace motor 

• The fan starts but there is not enough 
heat 

• Wrong setting of room thermostat 

• Check correct setting of room 
thermostat 

• Defective room thermostat 

• Replace room thermostat 

• The space heaters stops  

• Safety thermostat intervenes 

• Identify the problem that caused the 
overheating 

Содержание E3

Страница 1: ...ot for domestic use Space Heating Only Diesel Kerosene Fired Space Heater Not for domestic use Space Heating Only Spitwater Australia Pty Ltd T A Ottico Equipment 953 Metry Street Albury NSW 2640 Aust...

Страница 2: ...nner and purpose for which they were intended and in accordance with the recommendations and safety precautions detailed in this manual and in operating instructions and stickers on the unit itself Al...

Страница 3: ...options kW 1 5 3 0 6 66 10 0 10 0 15 0 14 7 22 0 20 0 30 0 Electric current A MAX 13 0 13 5 21 0 30 0 43 0 43 0 Air flow rate m3 h 450 1500 2000 3050 5100 6500 Electrical protection level IPX4 Noise...

Страница 4: ...rder to warn user of potential injury if not cautious Their meaning is listed next to them for your attention WARNING Hot surface Do not touch will result in injury WARNING Electric shock Disconnect p...

Страница 5: ...for use by persons with reduced physical sensory or mental capabilities orlack of experience or knowledge The heater is not to be installed in an area where there is a risk of fire or explosions Neve...

Страница 6: ...is DO NOT connect the unit have it replaced by an electrician or authorized service technician Type Yattachment DO NOT pull on the power cord in order to unplug the unit remove the plug from the powe...

Страница 7: ...id hazards 10 MAINTENANCE AND SERVICE The heater must be checked that it is safe and in proper working order before putting into service and before every use If the unit is damaged donot use it Always...

Страница 8: ...8 CONTROL BOARD Fig 1 1 ROOM THERMOSTAT 2 OVERHEATING THERMOSTAT MANUAL RESET 3 MAIN SWITCH 4 POWER SWITCH 5 LAMP 1 2 3 MOD 3 kW MOD 10 kW 15 kW 22 kW 4 1 3 4 2 5...

Страница 9: ...9 CONTROL BOARD Fig 1 1 ROOM THERMOSTAT 2 OVERHEATING THERMOSTAT MANUAL RESET 3 MAIN SWITCH 4 POWER SWITCH 5 LAMP 6 ROOM THERMOSTAT PLUG 6 2 MOD 30 kW 3 4 5 1...

Страница 10: ...may overheat make sure heater is always under surveillance and keep children and animals away from it at the end of each working period the main switch is disengaged Warning this unit may not be used...

Страница 11: ...mmediately a b Turn the knob 1 on the room thermostat to the desired temperature the electric heaters also start and continue running until the set temperature has been reached while the lamp 5 lights...

Страница 12: ...differentiated waste collection center in conformity to law Before scrapping the unit check the machine data plate if it bears the symbol it means that disposal is regulated by the Italian legislativ...

Страница 13: ...13 FOOT HANDLE ASSEMBLY INSTRUCTION MOD 3 kW MOD 10 kW 15 kW 22 kW...

Страница 14: ...14 FOOT HANDLE ASSEMBLY INSTRUCTION MOD 30 kW...

Страница 15: ...15 NOTES...

Страница 16: ...16...

Отзывы: