PAGE 40 of 54
Menu Structure
All similar data and running parameters are grouped in separate menus. Menus can be displayed and their
values modified (where accessible), by using the GSU.
Menu Selections
RUN menu
MIN/MAX menu
RC-Check menu
INFO menu
STATISTICS menu
LIMITS menu
TEST menu
Selecting a Menu
The corresponding buttons (hot keys) can directly select the “Run”, “Info”, “MIN/MAX”, or “Limits” menus.
An alternate method is to press and hold the
Select Menu
button and use the
+ / -
buttons for selecting.
Note:
this method is the only access to all menus.
Change Values / Items
In order to change an indicated value, press and hold the
Change Value/Item
button while using the
+ / -
buttons to alter its value. An arrow (
) will appear in front of the value, if it can be changed.
The RUN Menu
As soon as the ECU is switched on, the
Run
menu is displayed.
In the lower display line, the actual turbine RPM is indicated.
In the upper display line, the following selections can be monitored. Use the
+ / -
buttons alone for
selecting the different parameters.
Value
Explanation
Temp.
Current EGT (
E
xhaust
G
as
T
emperature).
The units, °C or °F can be selected in the LIMITs menu.
OffCnd
SetRpm
Last Off command (reason for shut down). See table on page 28
State
Current turbine state.
U-Pump
Current pump voltage.
AirSpeed
Current Air speed (km/h) this readout is usual for function check of the speed sensor.
Note : This readout is only supported by connected airspeed sensor.
SetSpeed
Target state-air speed (km/h). This readout is for checking at
the “speed control” mode
the set target state-airspeed of throttle stick.
Note: This readout is only supported by connected airspeed sensor.
Содержание RX Series
Страница 15: ...PAGE 15 of 54 Complete System Connection Diagram RXi...
Страница 16: ...PAGE 16 of 54 System Connection RXi Photo To fueltank To receiver...
Страница 29: ...PAGE 29 of 54 Flashing E EGT sensor defective Last Off Condition Low RPM shut off from previous run...
Страница 38: ...PAGE 38 of 54 Connection Diagram of the Smoke System...