jetboards.mx
-
USER AND SAFETY MANUAL - kymera
BATTERY STORAGE
The battery should never be left fully charged when not in use for an extended period of time. If
storing for more than (1) week make sure and discharge your battery to between 50%~53V.
When charging to store the chager should be stopped when it reads aprox 55V. The battery level
should then be checked every 60 days (or more where possible) to ensure it still retains above
40% (52V).
When storing your battery, the life can also be dramatically affected by the storage temperature.
Always store your battery in a cool bry secure area, and out of the reach of children.
permanent capacity loss VS. storage conditions
40% charge
2% loss after 1 year
4% loss after 1 year
15% loss after 1 year
25% loss after 1 year
BatteryUniversity.com
Storage Temperature
0 ºC (32 ºF)
25 ºC (77 ºF)
40 ºC (104 ºF)
60 ºC (140 ºF)
100% charge
60% loss after 1 year
20% loss after 1 year
35% loss after 1 year
40% loss after 1 year
5