16
9.4
Belt tension and replacement
1. Disconnect machine from power source.
2. Lower blade to its lowest point.
3. Loosen bolt (A, Figure 22).
4. Take tension off belt (B) by lifting up on motor.
5. Remove belt from arbor and motor pulleys.
6. Install new belt. The weight of the motor
should apply sufficient tension to belt. Tighten
bolt (A, Figure 22).
NOTE: New belts may stretch slightly until they are
worn in. Check belt tension after saw has been
used for a few hours, and adjust if necessary.
Figure 22
10.0
Maintenance
Always disconnect power to
the machine before performing maintenance.
Failure to comply may cause serious injury.
Use vacuum or compressed air to clear out cabinet
interior of sawdust and wood chips. Make sure
motor fan and fan cover are also kept clear of
sawdust.
Use a wire brush to clean worm gears and
trunnions. Apply white lithium grease or powdered
graphite to lubricate worm gears and trunnions.
Keep a light coat of rust-preventive on the table top
when not in use. If rust develops on tabletop,
remove it with WD-40
®
and a Scotch-Brite™ Hand
Pad.
The saw arbor is press fitted in the saw raising arm
housing. If the arbor ever needs to be removed for
bearing replacement, it should be done by a
qualified service technician. Call your customer
service representative at the phone number on the
front cover.
Содержание XACTA JTAS-12-DX
Страница 19: ...19 12 1 1 Table and Cabinet Assembly JTAS 12 DX Exploded View...
Страница 22: ...22 12 2 1 Trunnion and Motor Assembly JTAS 12 DX Exploded View...
Страница 25: ...25 12 3 1 Blade Guard Assembly JTAS 12 DX Exploded View...
Страница 27: ...27 13 0 Electrical Connections...
Страница 28: ...28 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...