background image

JAT-800 Pneumatic Needle Scaler 

 

25.  Give  your  work  undivided  attention.  Looking 

around,  carrying  on  a  conversation  and 
“horse-play” are careless acts that can result 
in serious injury. 

26.  Do not force a tool or attachment to do a job 

for  which  it  was  not  designed.  The  right  tool 
will do the job better and more safely. 

27.  Repetitive  motions  and/or  exposure  to 

constant  vibration  can  be  harmful  to  hands 
and  arms.  Take  frequent  breaks  and  relax 
hands  during  extended  operation.  Change 
posture to avoid discomfort or fatigue. 

28.  Compressed  air  can  be  harmful  if  directed 

toward sensitive areas of the body, and may 
propel small particles caught in the air stream. 
Exercise proper caution. 

29.  Use 

only 

recommended 

accessories; 

improper accessories may be hazardous. 

30.  Maintain  tools  with  care.  Keep  air  tool  clean 

and oiled for best and safest performance. 

31.  Do  not  use  combustible  gases,  carbon 

dioxide, oxygen  or  any  bottled  gas  as  an  air 
source for the tool. These can present risk of 
explosion and serious injury. 

32.  Do  not  lubricate  the  tool  with  combustible 

liquids, such as kerosene, diesel or jet fuel. 

33.  Do  not  dispose  of  this  tool  with  normal 

household waste. Never dispose of the air tool 
into fire. 

Specific warnings for Needle Scaler 

34.  A needle scaler is used to remove rust, scale, 

paint and such like from metal surfaces. If you 
are  not  familiar  with  the  proper  and  safe 
operation of a needle scaler, do not use until 
proper  training  and  knowledge  have  been 
obtained. 

35.  Secure workpiece with clamps or vise; do not 

hold workpiece by hand. 

36.  Use  both  hands  to  operate  needle  scaler. 

Keep hands away from needle area. 

37.  Use only needles specifically designed for use 

with a needle scaler. 

38.  Keep  needles  against  work  surface.  Do  not 

use excessive force – let the tool do the work. 

39.  If needle scaler will not remove material from 

the  work  surface,  discontinue  use.  Use 
alternate methods for removal. 

 

 

Familiarize  yourself  with  the  following  safety 
notices used in this manual: 

 

This means that if precautions 

are not heeded, it may result in serious, or even 
fatal, injury.

 

  

This means that if precautions 

are  not  heeded,  it  may  result  in  minor  injury 
and/or possible tool damage.

 

 

 

 

WARNING:

 This product can expose you 

to chemicals including lead which is known to 
the  State  of  California  to  cause  cancer  and 
birth  defects  or  other  reproductive  harm.  For 
more 

information 

go 

to 

http://www. 

p65warnings.ca. gov. 

 

WARNING:

 Some dust, fumes and gases 

created  by  power  sanding,  sawing,  grinding, 
drilling,  welding  and  other  construction 
activities contain chemicals known to the State 
of California to cause cancer and birth defects 
or other reproductive harm. Some examples of 
these chemicals are: 

  lead from lead based paint 

  crystalline  silica  from  bricks,  cement  and 

other masonry products 

  arsenic  and  chromium  from  chemically 

treated lumber 

Your  risk  of  exposure  varies,  depending  on 
how often you do this type of work. To reduce 
your  exposure  to  these  chemicals,  work  in  a 
well-ventilated  area  and  work  with  approved 
safety equipment, such as dust masks that are 
specifically  designed  to  filter  out  microscopic 
particles.  For  more  information  go  to 
http://www.p65warnings.ca.gov/  and  http:// 
www.p65warnings.ca.gov/wood. 

 

Содержание 505800

Страница 1: ...Pneumatic Needle Scaler 505800 JAT 800 Operation Parts Manual M 505800 Edition 2 11 2018 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2015 JET ...

Страница 2: ...on needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law Applies This wa...

Страница 3: ...p against the work surface 11 Do not operate air tool without its guards in place Do not modify the tool 12 Do not operate this tool while tired or under the influence of drugs alcohol or any medication 13 Adopt a comfortable posture with proper balance and maintain secure footing at all times Non slip footwear or anti skid floor strips are recommended 14 Do not wear loose clothing or jewelry Conf...

Страница 4: ...h clamps or vise do not hold workpiece by hand 36 Use both hands to operate needle scaler Keep hands away from needle area 37 Use only needles specifically designed for use with a needle scaler 38 Keep needles against work surface Do not use excessive force let the tool do the work 39 If needle scaler will not remove material from the work surface discontinue use Use alternate methods for removal ...

Страница 5: ...n this document The instructions and warnings in this manual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As with any tool operation safety of operator and bystanders should be first priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site...

Страница 6: ...lever Grip Inline Overall Length 15 in 381 mm Housing material Steel Net weight 6 28 lb 2 85 kg Shipping weight 6 68 lb 3 03 kg 1 The specified values are emission levels and are not necessarily to be seen as safe operating levels As workplace conditions vary this information is intended to allow the user to make a better estimation of the hazards and risks involved only Specifications were curren...

Страница 7: ...aler Clean only 6 to 8 inches of surface area at one time and make 2 or 3 passes 5 Hold needle scaler firmly with both hands at approximately 45 degree angle from work surface 6 Place needles upon work surface and press throttle lever Pressure against throttle lever determines speed of tool Do not exert excessive pressure against work surface let the tool do the work 7 Release throttle lever to st...

Страница 8: ...r the job Continued use in either capacity will cause damage to the tool Tool Pressure JET Air Tools operate on 70 to 100 psi pounds per square inch air pressure measured at the tool when the tool is operating Set tool to 90 psi unless indicated otherwise Pressure in excess of 100 psi will shorten the life of the tool Air System Recommendations Equip the air compressor intake with a replaceable ai...

Страница 9: ...JET 9 Figure 2 Recommended arrangement of air piping and air line system ...

Страница 10: ...nt lubrication Lubricate with air tool oil according to instructions in this manual Loss of power erratic action Low air pressure Verify compressor has proper CFM rating for tool Check compressor regulator setting set air pressure to 90 psi Check for loose connections Moisture or obstruction in air hose Air supply must be clean and dry Clean out air hose s and remove any kinks or bends Improper si...

Страница 11: ...ollowing pages To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available when you call so that we may serve you quickly and accurately ...

Страница 12: ...12 JAT 800 Pneumatic Needle Scaler 505800 JAT 800 Needle Scaler exploded view ...

Страница 13: ...9597 Lock ring 1 28 730218 Alignment shim 2 29 729608 Rear valve block 1 30 1012591 Pin 2 31 729604 Valve 1 Index Part No Description Qty 32 729606 Front valve block 1 33 730219 Piston 1 35 731008 Barrel sleeve 1 36 731009 Nose 1 37 731010 Key 1 38 730220 Driver retainer 1 39 730221 Retainer buffer 1 40 JAT800 40 Barrel 1 41 730222 Retainer cap 1 45 730224 Needle driver 1 46 N307 Needle set 3x180L...

Страница 14: ...14 JAT 800 Pneumatic Needle Scaler This page intentionally left blank ...

Страница 15: ...JET 15 This page intentionally left blank ...

Страница 16: ...16 JAT 800 Pneumatic Needle Scaler 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Отзывы: