background image

INSTRUCTION MANUAL

SOLAR INVERTER

 

IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: [email protected]

FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST 

DEALERS. V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B

Thank you for selecting and buying V-TAC Product. V-TAC will serve you 

the best. Please read these instructions carefully & keep this user manual 

handy for future reference. If you have any another query, please contact 

our dealer or local vendor from whom you have purchased the product. 

They are trained and ready to serve you at the best.

INTRODUCTION

Multi-Language Manual QR CODE

Please scan the QR code to access the manual

in multiple languages.

Summary of Contents for 11369

Page 1: ...AVELOW 9B Thank you for selecting and buying V TAC Product V TAC will serve you the best Please read these instructions carefully keep this user manual handy for future reference If you have any another query please contact our dealer or local vendor from whom you have purchased the product They are trained and ready to serve you at the best INTRODUCTION Multi Language Manual QR CODE Please scan t...

Page 2: ...her people In order to avoid personal injury damage to the inverter or other devices please strictly observe the following safety precautions This chapter mainly describes various warning symbols in operation manual and provides safety instructions for the installation operation maintenance and use of the series grid tied solar inverters ICONS This manual provides relevant information with icons t...

Page 3: ...ere is a danger of burning Do not touch It must be reliably grounded before operation Do not open the cover of inverters unauthorized The electrical parts and components inside the inverter are electrostatic Take measurements to avoid electrostatic discharge during rel evant operation The inverter must be reliably grounded Ensure that DC and AC side circuit breakers have been disconnected and wait...

Page 4: ...hes Only qualified electricians are allowed to install the inverter Do not put and install the inverter on or close to combustible materials Keep the installation site away from children and other public places Remove the metal jewelry such as ring and bracelet before installation and electrical connection to avoid electric shock Do cover solar modules with light tight materials before electrical ...

Page 5: ...e local dealer or supplier for maintenance In order to avoid irrelevant personnel from entering the mainte nance area during maintenance temporary warning labels must be placed to warn non professionals to enter or use fence for isolation Firstly disconnect all power supplies of the grid to the inverter before any maintenance and then disconnect the DC breakers and wait for at least 5 minutes unti...

Page 6: ...N C TN C S and TT grid connection When applied to the TT connection the N to PE voltage should be less than 30V SAFETY GUIDELINES PRODUCT APPEARANCE The recommended solar modules need to comply with IEC61730 Class A standard Figure 3 Products appearance ...

Page 7: ...system of the inverter confirming N o N ame Instructio n 1 Cover 2 LED display panel LED indicators 3 DC switch On off of the DC input optional 4 DC input port For the connection of solar modules 5 AC terminal For the connection of AC output 6 Communication port RS485 and EXT communication port 7 Cooling chamber 8 Radiator 9 Name plate For rated parameters and safety precautions of the inverter ...

Page 8: ...wer Single phase L N PE Single phase grid tied solar inverter Single phase grid tied solar inverter 3KW 2M 3000 5KW 2M 4600 ICONS CERTIFICATION Icons Instruction CE certification mark The inverter complies with the CE directive EU WEEE mark Cannot dispose of the inverter as household waste ...

Page 9: ...DIMENSIONS AND WEIGHT Figure 5 Inverter dimensions Table of inverter dimension and net weight Figure 6 Paper packages dimension Table of packages dimension and gross weight W H Model H mm W mm D mm Gross weight kg Packagin g Material 3KW 2M 5kW 2M 573 480 284 19 Paper ...

Page 10: ...grid tied solar system including the connection between solar modules public grid and inverter Read this chapter carefully and ensure all installation requirements are met before installation Only qualified electricians are allowed to install the inverter UNPACKING INSPECTION The inverter has been thoroughly tested and rigorously checked before delivery but damage may still occur during transportat...

Page 11: ...tallation should ensure that the inverter is reliably grounded and the material of grounded metal conductor should be consistent with the metal material reserved for the grounding of the inverter BEFORE INSTALLATION Installation tools Table of detailed delivery list of single phase inverter N O N A M E QUA N T IT Y 1 3KW 2M 5KW 2M 1 2 Installation bracket 1 3 Operation manual 1 4 Bolt M 5 20 2 5 E...

Page 12: ... releasing In generally below space requirement should be met Table of detailed installation space M inimum clearance Lateral 200mm Top 450mm Bottom 450mm Do not open the cover of the inverter or replace any part as incomplete inverter may cause electric shock and damage the device during operation ...

Page 13: ...d the installation mode vary with the different installation sites It is recommended to install the inverter vertically to the firm wall or metal bracket Here we take wall installation as an example to introduce the installation matters of the inverter As shown in the Fig 10 the overall installation of the inverter should be vertical to the horizontal surface Table of cable specifications Table of sp...

Page 14: ...tallation bracket through M8 hex socket cap screws 4 Finally fasten the inverter and the bracket with M5 screws and tighten the screws to 2 Nm For firm installation the operators cannot release the device until the inverter is installed on the bracket firmly Table of size of installation bracket Table of instruction of installation bracket Figure 10 Installation bracket of 0 75 3KW inverter Figure 1...

Page 15: ...cal injuries or even death during system operation All the electrical installation must conform to the national and local electrical safety regulations Ensure all the cables are installed firmly according to the specified safety requirements and free from any damage It is not allowed to close the AC and DC breakers before the inverter is electrically connected Note Read and follow the instructions...

Page 16: ... wiring of negative pole is the same as that of the positive pole Ensure the poles of solar modules are well connected with the connectors Figure 14 Connection between DC connector and solar modules PV strings can be connected to inverter only after protection measures which conform to local electrical regulations are taken and the technical parameters in this manual are fulfilled The PV string co...

Page 17: ...ing and short circuit protection measures in accordance with the local electrical safety codes 2 As shown in Figure 16 connect and fasten L N and PE conductors of the single phase AC grid to AC terminal and tighten to 0 5 Nm Assemble the AC terminal and tighten to 2 5 3 Nm then connect the terminal to the AC port of the inverter 3 Connect the DC output cable of the PV module to the DC connector wh...

Page 18: ...ed by LCD Refer to chapter 6 for LED state indicator and LCD display information In order to ensure a safe normal and stable operation of the PV power generation system all the newly installed renovated and repaired PV grid connected power generation system and its grid connected inverter must undergo inspection before running Start the inverter according to below steps to achieve grid connected o...

Page 19: ...tore the operation data Use real time monitoring software to read inverter running data regularly back up all inverter running data and stats Check the monitoring software and inverter LCD screen to make sure the parameters are set correctly Once each quarter Check inverter operation status Check to make sure the inverter installation is solid no damage or deformation When inverter running check t...

Page 20: ...pection power generation recoverable fault and unrecoverable fault LED indicators are on off and blinking Please refer to the table below for detailed state of inverter and LED indicators state LED indicator is off green yellow red LED indicator is blinking at every 0 25S or 0 5S Green yellow red LED indicator is on Table of inverter state and LED indicators Inverter state LED indicators Descriptio...

Page 21: ...ature abnormal E006 2 Inverter stand by DC input fault E001 Yellow indicator keeps on others off Unrecoverable fault Run Warn Fault Hardware or software fault E003 E004 E005 E008 E009 E011 E013 or E015 De couple the inverter from the system before maintenance Red indicator blinks in every 0 5s others off Run Warn Fault Current leakage or unqualified output power energy of the inverter E007 E010 E0...

Page 22: ...ry defaults Text Parameter Display Area Fault Code Status Area Figure 18 Main interface The main interface of the LCD screen is shown as the Figure above 1 The curve graph display area displays the power change curve of current day 2 Text parameter display area displays the key running parameters of current inverter operation which displays three rows of parameters every time Under running or slee...

Page 23: ...r saved peak power and total CO2 reduction in current day Latest 7 days Total power produced total power saved and total CO2 reduction in latest 7 days Latest 1 month Total power produced total power saved and total CO2 reduction in latest 1 month Latest 30 days Total power produced total power saved and total CO2 reduction in latest 30 days Latest 1 year Total power produced total power saved and...

Page 24: ... Setup menu can realize parameter setup shown in table of parameters setting LCD MENUS ...

Page 25: ...m LCD display Instruction RS485 Address R S 4 85 A dd re ss 0 01 1 Enter into the interface and edit the data through or And then press ENT again to the next bit After editing the three bits press ENT to save the edition and press ESC to exit ...

Page 26: ...he four bits press ENT to save the edition and press ESC to exit The currency types include EUR POD CNY and USD Setup Date Time S et up D at e T im e D at e 2 01 2 0 1 1 5 T im e 1 2 1 4 3 0 1 Enter into the interface and edit the date and time through or And then press ENT again to the next line After editing the four bits press ENT to save the edition and press ESC to exit Language Curr Language...

Page 27: ...actor Limit Mode Invalid Invalid Auto Manual Limit Power 100 Power Factor Grid Tied Mode Normal Mode Power Factor 1 00 Input password 0000 The password is needed when enter into the interface of Set power Get the password from the supplier if necessary There are 3 submenus P Lmt Mode invalid limited power function is invalid auto special for single phase manual set the limit of output value manual...

Page 28: ...me 0 20s ACUFFreqency 47 6Hz ACUFTime 0 20s ACOFFreqency 51 4Hz ACOFTime 0 20s Inputpassword 0000 Password is required when enter into the interface of Run Param Get the password from the supplier if necessary Set ACUV Volt ACUV time and others under the related submenus and then press and to modify and finally press ENT to confirm ...

Page 29: ... ACOF Time ACUV Volt phase volt ACUV Time ACOV Volt phase volt ACOV Time ACUF Frequency ACUF Time ACOF Frequency ACOF Time There are 2 protections under G83 G59 UK and PEA Thailand standards and there is only one protection under other grid tied standard Set ACUV Volt ACUV time and others under the related submenus and then press and to modify and finally press ENT to confirm Generally it is only ...

Page 30: ...which is shown in Figure 26 There are 8 pieces of fault information in the record which is shown in Figure 26 Otherwise it will display No Fault Refer to HISTORY for more detailed information INVERTER CONTROL Press and in the control interface and then press ENT to view the sub menu which is shown in Figure 27 System Information Part No Serial No Soft Ver Figure 24 System information S ys te m Ve r...

Page 31: ...rough the panel And save the all settings and operation record Press ENT to ensure restarting and the inverter will begin to self inspect or press ESC to return Record clear C le ar a ll R ec or d S ur e P re ss E NT t o ex ec ut e P re ss E SC t o ca nc el Press ENT to ensure clear all records or press ESC to return Record clear is to clear all setting parameters through the panel restore to the ...

Page 32: ...s been set through the following ways LCD Screen MENU Main Menu System Info System Information Cert Area Certificate Area V pv1 000 0V I pv1 000 0A V pv2 000 0V 01 A001 MENU Alarm p h MENU M ai n Me nu M on it P ar am H is to ry S ta ti st ic s S et up S ys te m In fo F au lt I nf o S et up M en u A dd re ss Keypad PWD C as h p ri ce D at e T im e L an gu ag e C ou nt ry Co un tr y C hi na Germany ...

Page 33: ...de of grid tied solar inverter is RS485 which includes RS485 M and RS485 S ports The RS485 M ports can communicate with private computers smart phones and so on The system monitoring solution is shown as Figure below Figure 28 Monitoring system of inverter STANDARD COMMUNICATION Table of pins on inverter instruction Pin on inverter Definition 1 Red 5VDC 2 Orange A RS485 3 Brown B RS485 4 Black GND...

Page 34: ...ion is correct 3 Please download the monitoring software WinExpert and its operation instruction from our website Please download the connection instruction operation manual and commissioning tools on website Note the optional accessories are not standard configured need to buy separately Table of Optional communication accessories 1 Connect the communication connector configured for the inverter to...

Page 35: ...ut OV Input overvoltage DC input overvoltage E003 Bus OV Bus overvoltage Internal bus voltage E004 Boost Fail Voltage boost fault Voltage boost fault of the inverter E005 Grid OC AC overcurrent Internal AC overcurrent E006 OTP Over temperature Internal over temperature E007 Riso Low Low isolation impedance Low isolation impedance of the external port system E008 IGBT drv IGBT drive protection IGBT...

Page 36: ...ction is enable E022 FreqChg Frequency is changed Fluctuation of grid voltage is over inverter normal sustainable range E023 PE Loss PE wire not connected The PE wire is unconnected this error code only available under AS4777 safety E024 MeterLoss The smart meter not connected The smart meter not connected E025 Locking The inverter is locked The inverter is locked E026 Run Limit Light load Light l...

Page 37: ...Operation temperature Relative humidity M ax altitude m Displaying Systerm language Communication DC terminal Noise dB A Installation mode Protection M odel Single phase Input DC Optional Output AC Voltage V frequency Hz 1 80 270Vac 50Hz 47 51 5Hz 60Hz 57 61 5Hz VDE01 26 AR N41 05 AS4777 2 AS4777 3 CQC G83 2 G59 3 C1 0 1 1 TF3 2 1 PEA 1 04A 37 2ms Less than 2 A 0 9 0 9 adjustable 3 rated power Sys...

Reviews: