BA-40100-02-V17 | 37
Operating instructions
19.1.17 Menu 5.2: Outputs
Main menu >> Menu 2 >> service >> outputs
The menu permits:
• Adjusting the parameters for the current configured type of output
(see chapter “7 Explanation of measuring values outputs” on
page 23).
• Adjusting the maximum limits for the outputs.
19.1.18 Menu 5.3: Auto setup (First system self-setting)
Main menu >> Menu 2 >> service >> autosetup
This menu allows you to perform automatic determination of the settings
of the disinfection controller (see chapter “18 Auto setup (First system
self-setting)” on page 29). The time for performing eventual adjust-
ments depends on the actual conditions of the control system (max time
is approx 4 hours).
19.1.19 Menu 5.4: Reset
Main menu >> Menu 2 >> service >> reset
The menu permits
• Reset: Reset the device using the same configuration
• Factory setting: Restart the instrument using the original default
settings (see chapter “22 Default settings” on page 53).
• The controller is switched off in a defined manner before being
disconnected from the power supply.
19.1.20 Menu 5.5: Network
Main menu >> Menu 2 >> service >> network
The menu permits the RS 485 network address to be set to connect the
controller to a PC or network.
19.1.21 Menu 5.6: Logbook
Main menu >> Menu 2 >> service >> log file
The data logger contains the full list of all settings done on your
TOPAX DX. It can be viewed as clear text on your TOPAX DX screen or
on your PC but in this case you must replace the existing memory card
(see chapter “24 Memory card” on page 54).
19.1.22 Menu 5.7: Time
Main menu >> Menu 2 >> service >> time
Menu for setting the time after a battery replacement.
The time automatically changes from summer time to winter time and
vice versa. This menu also allows you to switch off this changeover func-
tion.
19.1.23 Menu 5.8: Timer
Main menu >> Menu 2 >> service >> timer
In this menu you can adjust the timer of your instrument so that night-
time functions are automatically switched on and you allocate to indi-
vidual week days.
19.1.24 Menus 5.9 and 5.10: Code und service password
Main menu >> Menu 2 >> service >> password and service password
In these menus you can block the various levels by using a password (a
4-digit numerical code). All information menus remain available.
The password is activated 5 minutes after input.
Menu
Function
5.9 Password
When the password has been entered, the "Calibrate",
"Setpoints" and "Menu 2" menus can only be accessed
by entering this password.
5.10 Service
password
When a service password has been entered the "Service"
menu can only be accessed by entering this password.
If no password is set all program levels are accessible.
ATTENTION!
If you enter a protection code, the related menu will
be only accessible after entering the password. Enter
the password and press "OK" to confirm.
19.1.25 Menu 5.11: DIN contact / ECO contact
Main menu >> Menu 2 >> service >> DIN contact
This menu allows you to adjust the values and the lag time of switching
contact for energy-saving operation (see chapter “14 Economy mode -
DIN-contact and ECO-contact” on page 27).
19.1.26 Menu 5.12: Flocculation
Main menu >> Menu 2 >> service >> flocculation
Set the parameters required to operate and start the flocculation pump.
It is possible to select among the following operation modes:
Operating mode
Description
Off
-
On
with output capacity in %
Night-time economy
mode
with setting of separate %-wise output capacity for
day and night time operation.
flow-dependent
(disturbance
variable)
with output capacity in %
flow-dependent
(disturbance varia-
ble) and night-time
economy mode
with setting of separate %-wise output capacity for
day and night time operation.
Night-time operation is activated either by the timer or "externally" by
the user.
19.1.27 Menu 5.13: Alarm settings
Main menu >> Menu 2 >> service >> alarm settings
Use this menu to set the controller pattern and the alarm relay function
when an alarm occurs.
• Controller ON: the controller remains on if an alarm sounds
• Controller OFF: the controller goes off when an alarm sounds and
the control valve is closed
• Relay ON: the alarm relay is activated when an alarm is activated
• Relay OFF: the relay is activated when energized by the operating
current and is deactivated if an alarm goes on.
19.1.28 Menu 5.14: Start
Main menu >> Menu 2 >> service >> startup
In this menu you can adjust the lag time of the control functions. The
new time is effective after you have successfully:
• Calibration of the individual sensors
• Lack of sample water
• Filter cleaning
• After switching the power on