54 | BA-40100-02-V17
TOPAX
®
DX
Multichannel controller
23 Spare parts and options
Module, option, spare part or function
Order no.
Output board
5 relays, 3 optocoupler
78399
Input board
5-fold
Disinfection (CS 120 or encapsulated
electrode), pH-value, Redox, temperature,
position feedback servo motor, controller 1
78403
Input board
3-fold
Disinfection (potentiostat), 0/4-20 mA,
position feedback, servo motor controller 2
78404
RS 485 interface module
78406
Expansion module for measuring total chlorine content and
controlling bonded chlorine
78438
Expansion module for measuring and controlling conductivity
78439
Srew M4 x 6 (tool to open the casing)
38341
Hinge pivot
38336
fixing hing pivot at the top
38337
fixing hing pivot below
38338
Memory card
78405
24 Memory card
The memory card performs a number of tasks including the update of the
firmware, the transfer of language files and data logging.
The data which is saved on the card can be transferred to a PC by means
of a reading device. To do so, the memory card must be removed from the
device. To remove the memory card, the TOPAX DX must be switched off
in a specific way: Working in the "Service-reset" menu, press the “Shut-
down” button. All controllers are set to an output capacity of "0%" and all
unsaved data is saved to the memory card. The TOPAX DX can be operat-
ed further without a card (restart required). The memory card can be read
out to a PC with a card reading device.
Fig. 43: Slot for the memory card on the display board. The card is inserted on the
display circuit board in the front housing.
ATTENTION!
The memory card must only be inserted or removed
when the device is de-energised. Switch off the
TOPAX DX in the "Service-reset" menu.
ATTENTION!
Ensure that no additional files are saved on the memo-
ry card / that the saved data is not changed or deleted.
To prevent errors on the memory card, de-register the
card reader from the PC before removing the memory
card.
On its website, the manufacturer provides the free software "TopReader"
to read the memory card with the recorder and configuration data.
Various circumstances (e.g. malfunctions in the processor or similar) can
result in faulty data saving on the memory card; the TOPAX DX will no
longer start. In this case, remove the memory card from the TOPAX DX.
Files which can still be used can be saved on a PC.
ATTENTION!
TOPAX
®
only supports memory cards with FAT format-
ting and 512 Bytes sector size. As a result, the usable
capacity is restricted to 2 gigabyte. Only memory cards
from Lutz-Jesco GmbH should be used as a matter of
course.
IMPORTANT!
If a software update is to be performed, the memory card is
to be formatted with a special formatting programme. This
programme is available free-of-charge from Lutz-Jesco.