9
TEMPERATURE MEASUREMENTS
1. Set the function switch to the green
Temp
position.
2. Insert the Temperature Probe into the input jacks, making sure to observe the correct
polarity.
3. Press the
MODE
button to indicate
ºF
or
ºC
4. Touch the Temperature Probe head to the part whose temperature you wish to measure.
Keep the probe touching the part under test until the reading stabilizes (about 30
seconds).
5. Read the temperature in the display.
Note:
The temperature probe is fitted with a type K mini connector. A mini connector to
banana connector adaptor is supplied for connection to the input banana jacks.
CAPACITANCE MEASUREMENTS
WARNING:
To avoid electric shock, disconnect power to the unit under test and discharge
all capacitors before taking any capacitance measurements. Remove the batteries and
unplug the line cords.
1. Set the rotary function switch to the green
Ω CAP
position.
2. Insert the black test lead banana plug into the negative
COM
jack.
Insert the red test lead banana plug into the positive
V
jack.
3. Press the
MODE
button to indicate “
nF
” on the display.
4. Touch the test leads to the capacitor to be tested.
5. The test may take up to 3 minutes or more for large capacitors to charge. Wait until the
readings settle before ending the test.
6. Read the capacitance value in the display
FREQUENCY/DUTY CYCLE MEASUREMENTS (ELECTRONIC)
1. Set the rotary function switch to the green “
Hz %
” position.
2. Press the Hz/% button to indicate “
Hz
” in the display.
3. Insert the black lead banana plug into the negative
COM
jack and the red test lead banana
plug into the positive
Hz
jack.
4. Touch the test probe tips to the circuit under test.
5. Read the frequency on the display.
6. Press the
Hz/%
button again to indicate “
%
” on the display.
7. Read the % of duty cycle on the display.