Commissioning and running
During operation, motors can have hot surfaces. The
temperature of the linear motor can reach up to 80°C.
Monitoring equipment and the error messages of the
control devices must be continuously controlled.
Switch off the engine if deviations from normal operation
occur, eg increased temperatures, unusual noises,
increased vibrations, etc...
The slide of the linear motors in vertical alignment are
not self-locking when switching off the power.
8.1
Weight compensation
Improper opening of the weight compensation is
prohibited.
Make sure that during installation and maintenance
work, the pneumatic supply has been turned off and are
not the supply lines under pressure.
Use only clean and oil-free air.
8.2
Spring brake
Improper opening of the spring brake on
LINAX® Lxs/Lxu is prohibited.
Make sure that during installation and maintenance
work, the pneumatic supply has been turned off and are
not the supply lines under pressure.
Use only clean and oil-free air.
The air connections should be kept as short as possible.
The response time of the corresponding valve is to check
with the respective manufacturer.