background image

 
 
 

 

 
6.4

 

Screwing sequence 

 

In order to avoid distortion of the motor during 

mounting to a base plate, it is important to observe the 

sequence of screwing. The screws must be tightened 

from the inside alternately left and right to the outside 

 
 
 
 

6.5

 

Flatness practical test 

 

Before mounting the ground plate or the slider, please 

test how smooth the slider can be moved by hand. After 

tightening the screws, move the slider again by hand. 

There should not be any noticeable changes in 

smoothness, otherwise the contact surfaces have to be 

revised.  

 
 
 

7

 

Electrical connection 

 

A defective or incorrect power supply may result in 

irreparable damage to the machine.  

 

An earthing cable must be connected to the system at all 

times. 

 

Do not pull any plugs during operation! 

There is a danger to life or injury and the risk of material 

damage. 

 

Never disconnect electrical connections while they are 

under voltage. Before disconnecting, switch off the 

power supply and disconnect at least and wait at least 10 

seconds. 

 

The drives must not be connected to any other power 

supply than the one specified. 

 

Connectors with a screw device, must be screwed down 

accordingly. 

 

Use only original Jenny Science AG cables and do not 

modify them. 

 

 

Содержание LINAX

Страница 1: ...ber 2020 This documentation contains important safety and handling notes about LINAX linear motor axis ELAX electric slide and ROTAX rotary motor axis Improper handling of these motors and non observa...

Страница 2: ...4 Environment Conditions 4 5 Handling with Linearmotor axis 5 5 1 Carriage 5 5 2 Measuring system 5 6 Mechanical assembly 6 6 1 Tightening torques 6 6 2 Flatness for mounting on ground plate 6 6 3 Fl...

Страница 3: ...that objects made of steel or iron e g watches rings etc as well as technical devices e g computers credit cards hard disks etc which can be attracted influenced or destroyed by the magnetic field ar...

Страница 4: ...em has been damaged during transport When unpacking the system take care not to damage sensitive parts such as cables connectors encoder and motor The commissioning of damaged products is prohibited 4...

Страница 5: ...the linear motor on the cover plate 5 2 Measuring system Incorrect handling of the linear motor axes with a magnetic measuring system could erase parts of the magnetic measuring tape Prevent magnets e...

Страница 6: ...ss Screw 70 6 2 Flatness for mounting on ground plate If the linear motor axes are mounted on a base plate this must have a flatness of 0 01mm Otherwise the linear motor axis may be distorted when scr...

Страница 7: ...ontact surfaces have to be revised 7 Electrical connection A defective or incorrect power supply may result in irreparable damage to the machine An earthing cable must be connected to the system at al...

Страница 8: ...er 8 1 Weight compensation Improper opening of the weight compensation is prohibited Make sure that during installation and maintenance work the pneumatic supply has been turned off and are not the su...

Страница 9: ...nstruction manual contains copyright protected information All rights are reserved This document may not be in its entirety or partially copied duplicated or translated without the prior consent of Je...

Отзывы: