background image

6

Gas Pressure Regulator

The gas pressure regulator supplied with this cooktop must be 
used. The inlet pressure to the regulator should be as follows for 
proper operation:

Natural Gas:

Minimum pressure: 5" (12.7 cm) WCP

Maximum pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP

LP Gas:

Minimum pressure: 11" (27.9 cm) WCP

Maximum pressure: 14" (35.5 cm) WCP

Contact local gas supplier if you are not sure about the inlet 
pressure.

Burner Input Requirements

Input ratings shown on the model/serial rating plate are for 
elevations up to 2,000 ft (609.6 m). 

For elevations above 2,000 ft (609.6 m), ratings should be 
reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea 
level (not applicable for Canada). 

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 
1" water column pressure above the manifold pressure shown on 
the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The cooktop and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The cooktop must be isolated from the gas supply piping system 
by closing its individual manual shutoff valve during any pressure 
testing of the gas supply piping system at test pressures equal to 
or less than ½ psi (3.5 kPa).

INSTALLATION INSTRUCTIONS

Install Cooktop

Decide on the final location for the cooktop. Avoid drilling into or 
severing existing wiring during installation.

Gas on Glass Cooktop models only:

1. Using 2 or more people, place the cooktop upside down on a 

covered surface.

2. Remove foam strip from the package containing literature. 

Remove backing from foam strip. Apply foam strip adhesive-
side down around bottom of cooktop, flush with edge.

NOTE: The foam strip helps avoid damage to the underside 
of the cooktop glass from debris and helps the cooktop sit 
flat on uneven counters. 

3. Place cooktop right side up into the cutout.

NOTE: Make sure that the front edge of the cooktop is 
parallel to the front edge of the countertop. If repositioning is 
needed, lift entire cooktop up from cutout to avoid scratching 
the countertop.

Make Gas Connection

Typical flexible connection

1. Apply pipe-joint compound made for use with Natural and LP 

gas to the smaller thread ends of the flexible connector 
adapters (see C and G in following illustration). 

2. Attach one adapter to the gas pressure regulator and the 

other adapter to the gas shutoff valve. Tighten both adapters.

A. Cooktop base
B. Foam strip

C. Cooktop

WARNING

Excessive Weight Hazard

Use two or more people to move and install cooktop.

Failure to do so can result in back or other injury.

A

B

C

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Содержание JGC9430BDB

Страница 1: ...jured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and...

Страница 2: ...neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agenc...

Страница 3: ...indows doors and strong heating vents or fans All openings in the wall or floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions...

Страница 4: ...Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit break...

Страница 5: ...th LP gas piping or tubing size should be minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit use a or I D fle...

Страница 6: ...ng into or severing existing wiring during installation Gas on Glass Cooktop models only 1 Using 2 or more people place the cooktop upside down on a covered surface 2 Remove foam strip from the packag...

Страница 7: ...in burner base Burner caps should be level when properly positioned If burner caps are not properly positioned surface burners will not light Place burner grates over burners and caps 4 Plug into a g...

Страница 8: ...obs to OFF If burners do not light properly Turn surface burner control knob to the OFF position Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blow...

Страница 9: ...ence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas t...

Страница 10: ...ensions correctes La table de cuisson doit tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvert...

Страница 11: ...s de 30 36 91 4 cm sur les mod les de 36 B Zone de mati re combustible au dessus du plan de travail espace d limit par des lignes pointill es ci dessus C Distance de s paration de 30 76 2 cm ou plus e...

Страница 12: ...ion doit satisfaire aux prescriptions de la plus r cente dition du code national am ricain en vigueur National Fuel Gas Code ANSI Z223 1 ou la norme CAN CGA B149 IMPORTANT Les tests de fuite de la tab...

Страница 13: ...an uvres d ouverture fermeture Ne pas entraver l acc s au robinet d arr t manuel Le robinet d arr t manuel est pr vu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson R gulateur de pr...

Страница 14: ...dement typique par raccord flexible 1 Appliquer sur les extr mit s filet es les plus petites des adaptateurs de raccords flexibles de connexion voir C et G sur l illustration qui suit un compos d tanc...

Страница 15: ...leur correctement plac doit tre horizontal Si le chapeau de br leur n est pas correctement plac le br leur ne peut s allumer Placer les grilles de br leur sur les br leurs et les chapeaux 4 Brancher...

Страница 16: ...leurs ne s allument pas correctement Ramener le bouton de commande du br leur de surface la position OFF V rifier que le cordon d alimentation est branch et correctement aliment fusible grill disjonc...