Jenn-Air JGC9430BDB Скачать руководство пользователя страница 3

3

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do 
not obstruct flow of combustion and ventilation air. 

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the underside of the 
cooktop base.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

The cooktop must be a specified cooktop that is approved to 
be installed either alone or over an undercounter built-in 
oven. Check the cooktop base approved installation label for 
your cooktop model number and approved combinations of 
cooktops and ovens that can be installed. If you do not find 
this label, your cooktop may not be approved for use over an 
undercounter built-in oven. Contact your dealer to confirm 
that your cooktop is approved.

Ovens approved for this type of installation will have an 
approval label located on the top of the oven. If you do not 
find this label, contact your dealer to confirm that your oven is 
approved. Refer to oven manufacturer’s Installation 
Instructions for approval for built-in undercounter use and 
proper cutout dimensions.

The cooktop should be installed in a location away from 
strong draft areas, such as windows, doors and strong 
heating vents or fans.

All openings in the wall or floor where cooktop is to be 
installed must be sealed.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

Grounded electrical supply is required. See “Electrical 
Requirements” section. Proper gas supply connection must 
be available. See “Gas Supply Requirements” section.

The cooktop is designed to hang from the countertop by its 
side or rear flanges.

The gas and electric supply should be located as shown in 
“Cabinet Dimensions” section so that they are accessible 
without requiring removal of the cooktop.

Provide cutout in right rear corner of cutout enclosure as 
shown to provide clearance for gas inlet, power supply cord, 
and to allow the rating label to be visible.

IMPORTANT: To avoid damage, check with your builder or 
cabinet supplier to make sure that the materials used will not 
discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the 
Manufactured Home Construction and Safety Standard, Title 
24 CFR, Part 3280 (formerly the Federal Standard for Mobile 
Home Construction and Safety, Title 24, HUD Part 280). When 
such standard is not applicable, use the Standard for 
Manufactured Home Installations, ANSI A225.1/NFPA 501A or 
with local codes.

In Canada, the installation of this cooktop must conform with the 
current standards CAN/CSA-A240-latest edition, or with local 
codes.

Product Dimensions

30" (76.2 cm) Model

36" (91.4 cm) Model

A. Model/serial rating plate

A

A. 30" (76.2 cm)
B. 21½" (54.6 cm)

C. 3

¹³⁄₁₆

" (9.7 cm)

D. 5¼" (13.3 cm)

E. 12¼" (31.1 cm)

A. 35

⁵⁄₁₆

" (89.7 cm)

B. 21" (53.3 cm)
C. 3

¹³⁄₁₆

" (9.7 cm)

D. 5¼" (13.3 cm)

E. 15¼" (38.7 cm)

A

B

C

D

E

A

B

C

D

E

Содержание JGC9430BDB

Страница 1: ...jured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and...

Страница 2: ...neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agenc...

Страница 3: ...indows doors and strong heating vents or fans All openings in the wall or floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions...

Страница 4: ...Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit break...

Страница 5: ...th LP gas piping or tubing size should be minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit use a or I D fle...

Страница 6: ...ng into or severing existing wiring during installation Gas on Glass Cooktop models only 1 Using 2 or more people place the cooktop upside down on a covered surface 2 Remove foam strip from the packag...

Страница 7: ...in burner base Burner caps should be level when properly positioned If burner caps are not properly positioned surface burners will not light Place burner grates over burners and caps 4 Plug into a g...

Страница 8: ...obs to OFF If burners do not light properly Turn surface burner control knob to the OFF position Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blow...

Страница 9: ...ence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas t...

Страница 10: ...ensions correctes La table de cuisson doit tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvert...

Страница 11: ...s de 30 36 91 4 cm sur les mod les de 36 B Zone de mati re combustible au dessus du plan de travail espace d limit par des lignes pointill es ci dessus C Distance de s paration de 30 76 2 cm ou plus e...

Страница 12: ...ion doit satisfaire aux prescriptions de la plus r cente dition du code national am ricain en vigueur National Fuel Gas Code ANSI Z223 1 ou la norme CAN CGA B149 IMPORTANT Les tests de fuite de la tab...

Страница 13: ...an uvres d ouverture fermeture Ne pas entraver l acc s au robinet d arr t manuel Le robinet d arr t manuel est pr vu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson R gulateur de pr...

Страница 14: ...dement typique par raccord flexible 1 Appliquer sur les extr mit s filet es les plus petites des adaptateurs de raccords flexibles de connexion voir C et G sur l illustration qui suit un compos d tanc...

Страница 15: ...leur correctement plac doit tre horizontal Si le chapeau de br leur n est pas correctement plac le br leur ne peut s allumer Placer les grilles de br leur sur les br leurs et les chapeaux 4 Brancher...

Страница 16: ...leurs ne s allument pas correctement Ramener le bouton de commande du br leur de surface la position OFF V rifier que le cordon d alimentation est branch et correctement aliment fusible grill disjonc...

Отзывы: