Make Gas Connection

To Assemble Pressure Regulator:

1. 

Install the pressure regulator with the arrow pointing up 

toward the bottom of the burner box and in a position 

where you can reach the regulator.

IMPORTANT:

 All connections must be wrench-tightened. Do 

not make connections to the gas regulator too tight. Making 

the connections too tight may crack the regulator and cause 

a gas leak. Do not allow the regulator to turn on the pipe 

when tightening fittings.

2. 

Connect the flexible stainless steel connector to the pressure 

regulator using a 1/2" (1.3 cm) male pipe thread adapter.
A combination of pipe fittings must be used to connect the 

cooktop to the existing gas line. Shown in the following 

illustration is a typical connection. Your connection may 

be different, according to the supply line type, size, and 

location.

NOTE:

 When installing the cooktop above a built-in oven, 

install a 90º elbow - 1/2" (1.3 cm) female to 1/2" (1.3 cm) 

male between the cooktop manifold pipe and the pressure 

regulator. The regulator must be set with the arrow pointing 

toward the cooktop. Apply pipe joint compound for use with 

Propane gas to the end of the cooktop manifold pipe and the 

male end of the 90° elbow.

Use only pipe-joint compound made for use with Natural and 

Propane gas.
Do not use TEFLON

®†

 tape. You will need to determine the 

fittings required depending on your installation.

Typical flexible connection

1. 

Apply pipe-joint compound made for use with Propane gas 

to the larger thread ends of the flexible connector adapters 

(see B and F in the following illustration).

2. 

Attach one adapter to the gas pressure regulator and 

the other adapter to the gas shut-off valve. Tighten both 

adapters.

3. 

Use a 15/16" (2.4 cm) combination wrench and channel lock 

pliers to attach the flexible connector to the adapters. Check 

that connector is not kinked.

No appliance/obstructions 

below cooktop

Suggested installation to 

avoid interference below 

cooktop

A

B

C
D

E

F

G

H

I

A

B

C

D
E
F

I

G

H

A.  Manifold entrance
B.  Gas pressure regulator
C.  Use pipe-joint compound.
D.  Adapter (must have 1/2" 

[1.3 cm] male pipe thread)

E.  Flexible connector
F. Adapter
G. Use pipe-joint compound.
H.  Manual gas shut-off valve
I.  1/2" (1.3 cm) or 3/4" (1.9 cm) 

gas pipe

A.  Manifold entrance
B.  Elbow (1/2" [1.3 cm] female to 

1/2" [1.3 cm] male)

C.  Flexible connector (pass 

through wall between cabinets)

D.  Adapter (must have 1/2" 

[1.3 cm] male pipe thread)

E.  Use pipe-joint compound.
F.  Appliance pressure regulator 

(supplied)

G. 1/2" (1.3 cm) or 3/4" (1.9 cm) 

gas pipe

H.  Manual gas shut-off valve
I.  1/2" (1.3 cm) or 3/4" (1.9 cm) 

gas pipe

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make 

sure gas pressure does not exceed 14" (36 cm) water 

column. 
Examples of a qualified person include: 
licensed heating personnel, 

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

A

C

D

B

A.  Gas pressure regulator
B.  Up arrow - regulator must be installed 

with arrow pointing up at cooktop bottom.

C.  Adapter (must have 1/2" [1.3 cm] male pipe thread)
D.  UL Listed or CSA Approved flexible 

stainless steel gas supply line

®

TEFLON is a registered trademark of Chemours.

Содержание JGC3115GS

Страница 1: ...the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING W11030506D IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installati...

Страница 2: ...not always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do...

Страница 3: ...where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded and polarized electrical supply is required See...

Страница 4: ...is not recommended for countertops with a molded backsplash Do not silicone seal in place Multi Unit Flush Dimensions Units Recessed Area Width D Cutout Width C One 15 38 1 cm unit 151 8 38 4 cm 143...

Страница 5: ...possible due to the normal operating nature of electronic gas cooktops The wiring diagram is provided with this cooktop It is located inside the cooktop burner box Gas Supply Requirements Observe all...

Страница 6: ...to the regulator should be as follows for proper operation Natural Gas Minimum pressure 6 15 2 cm WCP Maximum pressure 14 35 5 cm WCP Propane Gas Minimum pressure 11 27 9 cm WCP Maximum pressure 14 35...

Страница 7: ...top sit flat on uneven countertops Do not silicone seal in place Install Cooktop Install the pressure regulator to the cooktop before installing the cooktop See the Make Gas Connections section Multi...

Страница 8: ...he following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shut off valve Tighten both adapters 3 Use a 15 16 2 4 cm combination wrench and channel l...

Страница 9: ...hin 4 seconds The first time a surface burner is lit it may take longer than 4 seconds to light because of air in the gas line 2 Turn the control knob to HI and check for a blue colored flame It shoul...

Страница 10: ...10 Notes...

Страница 11: ...u un d c s Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE...

Страница 12: ...tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l empla...

Страница 13: ...unit s de 15 38 1 cm 45 114 3 cm 447 16 112 9 cm Quatre unit s de 15 38 1 cm 60 152 4 cm 597 16 151 0 cm Table de cuisson 30 76 2 cm et une unit de 15 38 1 cm 45 114 3 cm 443 8 112 7 cm Table de cuis...

Страница 14: ...e d un syst me d allumage lectronique qui ne fonctionnera pas en cas de branchement sur un circuit avec disjoncteur de fuite la terre Si les codes le permettent et si on utilise un conducteur distinc...

Страница 15: ...cier inoxydable de 5 8 1 6 cm con u par CSA pour raccorder la table de cuisson la canalisation rigide d alimentation en gaz REMARQUE Dans le cas d installations multiples une seule vanne de fermeture...

Страница 16: ...etirer l endos de la bande de mousse Pour les installations sur le comptoir Appliquer le c t adh sif de la bande de mousse sur le plan de travail 1 16 1 6 mm pr s des bords de l ouverture avant arri r...

Страница 17: ...rd d adaptation sur le robinet d arr t de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une cl mixte de 15 16 2 4 cm et une pince multiprise pour fixer le raccord flexible sur les racc...

Страница 18: ...allumage initial du br leur de surface le d lai d allumage peut tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz 2 Tourner le bouton de commande la position HI lev e...

Страница 19: ...19 Notes...

Страница 20: ...W11030506D 2017 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 11 17...

Отзывы: