WARNING: If the information in this manual is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this 
or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's 
instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or 
the gas supplier.

WARNING: 

Gas leaks cannot always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.

IMPORTANT: 

Do not install a ventilation system that blows air downward toward this gas cooking appliance. This type of 

ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or 

unintended operation.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by 

the State of Massachusetts.

Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.
A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).

Содержание JGC3115GS

Страница 1: ...the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING W11030506D IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installati...

Страница 2: ...not always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do...

Страница 3: ...where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded and polarized electrical supply is required See...

Страница 4: ...is not recommended for countertops with a molded backsplash Do not silicone seal in place Multi Unit Flush Dimensions Units Recessed Area Width D Cutout Width C One 15 38 1 cm unit 151 8 38 4 cm 143...

Страница 5: ...possible due to the normal operating nature of electronic gas cooktops The wiring diagram is provided with this cooktop It is located inside the cooktop burner box Gas Supply Requirements Observe all...

Страница 6: ...to the regulator should be as follows for proper operation Natural Gas Minimum pressure 6 15 2 cm WCP Maximum pressure 14 35 5 cm WCP Propane Gas Minimum pressure 11 27 9 cm WCP Maximum pressure 14 35...

Страница 7: ...top sit flat on uneven countertops Do not silicone seal in place Install Cooktop Install the pressure regulator to the cooktop before installing the cooktop See the Make Gas Connections section Multi...

Страница 8: ...he following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shut off valve Tighten both adapters 3 Use a 15 16 2 4 cm combination wrench and channel l...

Страница 9: ...hin 4 seconds The first time a surface burner is lit it may take longer than 4 seconds to light because of air in the gas line 2 Turn the control knob to HI and check for a blue colored flame It shoul...

Страница 10: ...10 Notes...

Страница 11: ...u un d c s Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE...

Страница 12: ...tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l empla...

Страница 13: ...unit s de 15 38 1 cm 45 114 3 cm 447 16 112 9 cm Quatre unit s de 15 38 1 cm 60 152 4 cm 597 16 151 0 cm Table de cuisson 30 76 2 cm et une unit de 15 38 1 cm 45 114 3 cm 443 8 112 7 cm Table de cuis...

Страница 14: ...e d un syst me d allumage lectronique qui ne fonctionnera pas en cas de branchement sur un circuit avec disjoncteur de fuite la terre Si les codes le permettent et si on utilise un conducteur distinc...

Страница 15: ...cier inoxydable de 5 8 1 6 cm con u par CSA pour raccorder la table de cuisson la canalisation rigide d alimentation en gaz REMARQUE Dans le cas d installations multiples une seule vanne de fermeture...

Страница 16: ...etirer l endos de la bande de mousse Pour les installations sur le comptoir Appliquer le c t adh sif de la bande de mousse sur le plan de travail 1 16 1 6 mm pr s des bords de l ouverture avant arri r...

Страница 17: ...rd d adaptation sur le robinet d arr t de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une cl mixte de 15 16 2 4 cm et une pince multiprise pour fixer le raccord flexible sur les racc...

Страница 18: ...allumage initial du br leur de surface le d lai d allumage peut tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz 2 Tourner le bouton de commande la position HI lev e...

Страница 19: ...19 Notes...

Страница 20: ...W11030506D 2017 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 11 17...

Отзывы: