background image

9

Complete Connection

1. 

Open the manual shut-off valve in the gas supply line. The 

valve is open when the handle is parallel to the gas pipe.

2. 

Test all connections by brushing on an approved 

noncorrosive leak-detection solution. If bubbles appear, 

a leak is indicated. Correct any leak found.

NOTE:

 When a single shut-off valve is used for a multi-unit 

installation, closing the valve will shut off the gas supply to 

all connected units.

3. 

Install all burner caps and burner bases.

A

B

C

Single Burner

A. Cap
B. Spreader
C. Electrode

Double Burner

A. Cap
B. Spreader
C. Electrode 

Single and Double Burner installation:

To install the spreader (B), insert the electrode (C) into the 

spreader hole. Install the cap (A) on the spreader (B).

Dual Flame Burner:

Install the inner and outer caps (A and B) on the dual 

flame burner.

Install surface grate:

The surface grate is positioned correctly when it sits level 

on the cooktop and does not rock or wobble.

4. 

Plug into a grounded 3 prong outlet.

Complete Installation

Electronic Ignition System

Check Operation of Surface Burners

1. 

Push in and turn the surface burner control knobs to IGNITE.
The surface burner flame should light within 4 seconds. 

The first time a surface burner is lit, it may take longer than 

4 seconds to light because of air in the gas line.

2. 

Turn the control knob to HI and check for a blue-colored 

flame. It should be clean and soft in character. No yellow tip, 

blowing, or lifting of flame should occur. Occasional orange 

flashes are normal and reflect different elements in the air 

or gas.

3. 

Repeat for LO.

NOTE:

 For the double burner, only the inner ring will have 

a flame.

4. 

Repeat for SIMMER.

5. 

After verifying the proper burner operation, turn the control 

knobs to OFF.

If burners do not light properly:

 

Turn the surface burner control knob to OFF.

 

Check that the power supply cord is plugged in and the 

circuit breaker has not tripped or the fuse blown.

 

Check that the gas shut-off valve is set to the open position.

 

Check that the burner bases and caps are properly 

positioned on the burners.

Recheck the operation of the surface burners. If a burner does 

not light at this point, call 

1-800-JENN-AIR (1-800-536-6247)

.

B

A

A.  Closed valve
B.  Open valve

A

B

C

D

Dual Flame Burner

A.  Inner cap
B.  Outer cap
C. Spreader
D. Electrode

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

A. Correct
B. Incorrect

Содержание JGC3115GS

Страница 1: ...the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING W11030506D IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installati...

Страница 2: ...not always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do...

Страница 3: ...where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded and polarized electrical supply is required See...

Страница 4: ...is not recommended for countertops with a molded backsplash Do not silicone seal in place Multi Unit Flush Dimensions Units Recessed Area Width D Cutout Width C One 15 38 1 cm unit 151 8 38 4 cm 143...

Страница 5: ...possible due to the normal operating nature of electronic gas cooktops The wiring diagram is provided with this cooktop It is located inside the cooktop burner box Gas Supply Requirements Observe all...

Страница 6: ...to the regulator should be as follows for proper operation Natural Gas Minimum pressure 6 15 2 cm WCP Maximum pressure 14 35 5 cm WCP Propane Gas Minimum pressure 11 27 9 cm WCP Maximum pressure 14 35...

Страница 7: ...top sit flat on uneven countertops Do not silicone seal in place Install Cooktop Install the pressure regulator to the cooktop before installing the cooktop See the Make Gas Connections section Multi...

Страница 8: ...he following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shut off valve Tighten both adapters 3 Use a 15 16 2 4 cm combination wrench and channel l...

Страница 9: ...hin 4 seconds The first time a surface burner is lit it may take longer than 4 seconds to light because of air in the gas line 2 Turn the control knob to HI and check for a blue colored flame It shoul...

Страница 10: ...10 Notes...

Страница 11: ...u un d c s Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE...

Страница 12: ...tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l empla...

Страница 13: ...unit s de 15 38 1 cm 45 114 3 cm 447 16 112 9 cm Quatre unit s de 15 38 1 cm 60 152 4 cm 597 16 151 0 cm Table de cuisson 30 76 2 cm et une unit de 15 38 1 cm 45 114 3 cm 443 8 112 7 cm Table de cuis...

Страница 14: ...e d un syst me d allumage lectronique qui ne fonctionnera pas en cas de branchement sur un circuit avec disjoncteur de fuite la terre Si les codes le permettent et si on utilise un conducteur distinc...

Страница 15: ...cier inoxydable de 5 8 1 6 cm con u par CSA pour raccorder la table de cuisson la canalisation rigide d alimentation en gaz REMARQUE Dans le cas d installations multiples une seule vanne de fermeture...

Страница 16: ...etirer l endos de la bande de mousse Pour les installations sur le comptoir Appliquer le c t adh sif de la bande de mousse sur le plan de travail 1 16 1 6 mm pr s des bords de l ouverture avant arri r...

Страница 17: ...rd d adaptation sur le robinet d arr t de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une cl mixte de 15 16 2 4 cm et une pince multiprise pour fixer le raccord flexible sur les racc...

Страница 18: ...allumage initial du br leur de surface le d lai d allumage peut tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz 2 Tourner le bouton de commande la position HI lev e...

Страница 19: ...19 Notes...

Страница 20: ...W11030506D 2017 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 11 17...

Отзывы: