Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.
©2005 Maytag Services
16026929
15
Component Testing Procedures
Illustration Component
Test
Procedure
Results
Oven light & housing
Disconnect connector and test
resistance of terminals...........................
Measure voltage at oven light................
Verify bulb is properly inserted.
Continuity with bulb inserted.
120 VAC, see wiring diagram for terminal
identification.
If voltage is not present at oven light,
check wiring or light switches.
Door plunger switch
Remove switch from unit and measure
the following points:
Door closed........................................
Door open ..........................................
COM-NO= Continuity (closed)
COM-NO= Infinity (open)
Autolatch assembly
Disconnect wires and test for
continuity per wiring diagram. .................
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
See wiring diagram for schematic layout.
Common is in neutral position unless
locking or unlocking autolatch assembly.
COM NO
Door lock switch
Switch connection in the following
positions:
Door latch locked ................................
Door latch unlocked ............................
COM-NO= Continuity (closed)
COM-NO= Infinity (open)
(JDS8850BD*)
Pressure regulator
Verify gas pressure (W.C.P.). .................
If on LP service verify proper gas
supply conversion.
5
"
Natural
10
"
LP/propane
(JDS986*BD*)
Pressure regulator
Verify gas pressure (W.C.P.). .................
If on LP service verify proper gas
supply conversion.
5
"
Natural
10
"
LP/propane
Top surface burner
5 K btu
9.2 K btu
16 K btu
Verify gas is supplied.............................
Verify cap is positioned correctly ...........
Gas supplied.
Check for obstructions in burner ports.
(JDS8850BD*)
Top surface,
dual burner
15 K btu
Inner: 3 K btu
Outer: 12 K btu
Verify gas is supplied.............................
Verify cap is positioned correctly ...........
Gas supplied.
Check for obstructions in burner ports.
Top surface,
burner cap
5 K btu
9.2 K btu
16 K btu
Verify cap is positioned correctly ........... Check for obstructions in burner ports.
(JDS8850BD*)
Top surface,
burner cap, dual
(inner and outer
burners)
Verify cap is positioned correctly ........... Check for obstructions in burner ports.
Содержание JDS8850BD
Страница 38: ...A 8 16026929 2006 Maytag Services Installation Instructions ...
Страница 39: ... 2006 Maytag Services 16026929 A 9 Installation Instructions ...
Страница 40: ...A 10 16026929 2006 Maytag Services Installation Instructions ...
Страница 41: ... 2006 Maytag Services 16026929 A 11 Installation Instructions ...
Страница 42: ...A 12 16026929 2006 Maytag Services Installation Instructions ...
Страница 43: ... 2006 Maytag Services 16026929 A 13 Installation Instructions ...
Страница 44: ...A 14 16026929 2006 Maytag Services Installation Instructions ...
Страница 67: ... 2006 Maytag Services 16026929 C 1 Appendix C ...