Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
16 16026929
© 2006 Maytag Services
Illustration Component
Test
Procedure
Results
L
A
B
A1
B1
N
Spark module 4 + 0
Test for voltage at terminals L and N .....
Check polarity and ground .....................
120 VAC
See wiring diagram.
Snap switch
(pan switch)
NOTE:
Downdraft
fan will not engage
if this switch is not
activated.
Test for voltage at terminals...................
Disconnect wiring and check for
continuity in LITE position ......................
120 VAC
Continuity in LITE position.
(JDS8850BD*)
Dual burner valve
Verify gas is supplied .............................
Orifices adjusted for
Natural or LP.
Gas supplied.
Burner valve,
push-to-turn, 270°
5 K btu
9.2 K btu
16 K btu
Verify gas is supplied .............................
Orifice adjusted for
Natural or LP.
Adjust set screw for simmer control.
Gas supplied.
(JDS986*BD*)
Burner valve,
push-to-turn, 270°,
E-burner
Verify gas is supplied .............................
Orifice adjusted for
Natural or LP.
Adjust set screw for simmer control.
Gas supplied.
Orifice holder
5 K btu
9.2 K btu
16 K btu
Verify gas pressure ................................
Check orifice for debris ..........................
5
"
Natural
10
"
LP/propane
Clean as needed.
(JDS8850BD*)
Orifice holder,
dual burner
12 K btu
3 K btu
Verify gas pressure ................................
Check orifice for debris ..........................
5
"
Natural
10
"
LP/propane
Clean as needed.
(JDS8850BD*)
Spark switch
Test for voltage at terminals...................
Disconnect wiring and check for
continuity in LITE position ......................
120 VAC
Continuity in LITE position.
(JDS986*BD*)
Spark switch
Test for voltage at terminals...................
Disconnect wiring and check for
continuity in LITE position ......................
120 VAC
Continuity in LITE position.
(JDS986*BD*)
Double valve switch
Test for voltage at terminals...................
Disconnect wiring and check for
continuity in LITE position ......................
120 VAC
Continuity in LITE position.
Spark ignition
electrode
Test for resistance of spark lead ............
Test ignitor to chassis ............................
Continuity
No continuity from ignitor to chassis.
Temperature sensor
Measure resistance................................ Approx 1000
Ω
at room temperature,
75° F (23.8° C).
Содержание JDS8850BD
Страница 38: ...A 8 16026929 2006 Maytag Services Installation Instructions ...
Страница 39: ... 2006 Maytag Services 16026929 A 9 Installation Instructions ...
Страница 40: ...A 10 16026929 2006 Maytag Services Installation Instructions ...
Страница 41: ... 2006 Maytag Services 16026929 A 11 Installation Instructions ...
Страница 42: ...A 12 16026929 2006 Maytag Services Installation Instructions ...
Страница 43: ... 2006 Maytag Services 16026929 A 13 Installation Instructions ...
Страница 44: ...A 14 16026929 2006 Maytag Services Installation Instructions ...
Страница 67: ... 2006 Maytag Services 16026929 C 1 Appendix C ...