
194
195
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
36"/30" TELESCOPING DOWNDRAFT VENTILATION
JXD7036YS – 36" x 42
1
⁄
8
" x 12
1
⁄
8
"
JXD7030YS – 30" x 42
1
⁄
8
" x 12
1
⁄
8
"
PRODUCT DIMENSIONS
FRONT VIEW
MODEL #
JXD7036YS
JXD7030YS
in
cm
in
cm
A
Overall width
36
91.4
30
76.2
B
Width of retractable vent
33
83.3
27
68.6
C
Width of blower motor box
16
1
⁄
2
42.0
16
1
⁄
2
42.0
D
Width of vent box
33
1
⁄
4
84.5
27
1
⁄
4
69.2
E
Height of top trim
1
⁄
2
1.3
1
⁄
2
1.3
F
Height of retractable vent
13
33.0
13
33.0
G
Height of end cap
1
⁄
8
0.3
1
⁄
8
0.3
H
Height of blower motor box
13
1
⁄
8
33.4
13
1
⁄
8
33.4
I
Height of vent box
28
1
⁄
2
72.4
28
1
⁄
2
72.4
J
Depth of top trim
2
5.1
2
5.1
K
Depth of retractable vent
1
1
⁄
2
3.8
1
1
⁄
2
3.8
L
Depth of vent box
2
1
⁄
8
5.4
2
1
⁄
8
5.4
M
Depth of blower motor box
10
25.4
10
25.4
N
Overall depth
12
1
⁄
8
30.8
12
1
⁄
8
30.8
O
Depth of reverse blower
4
3
⁄
4
12.1
4
3
⁄
4
12.1
A
B
C
H
D
F
I
E
G
J
K
L
J
K
L
M
N
O
P
O
M
H
HH
HH
HH
A
B
C
H
D
F
I
E
G
J
K
L
J
K
L
M
N
O
P
O
M
H
HH
HH
HH
SIDE VIEW
A
B
C
H
D
F
I
E
G
J
K
L
J
K
L
M
N
O
P
O
M
H
HH
HH
HH
REVERSE BLOWER INSTALLATION –
SIDE VIEW
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
OPENING/CLEARANCE DIMENSIONS
FRONT VIEW
MODEL #
JXD7036YS
JXD7030YS
in
cm
in
cm
A
Width of cutout
33
1
⁄
2
85.9
27
1
⁄
2
69.9
B
Depth from center of vent cutout to back wall –
floor vent option
10
25.4
10
25.4
C
Height from center of vent cutout to
countertop – side wall vent option
21
3
⁄
8
54.1
21
3
⁄
8
54.1
D
Depth from back wall to vent box cutout (min.)
1
⁄
2
1.3
1
⁄
2
1.3
E
Depth from center of vent cutout to back wall –
side wall vent option
10
25.4
10
25.4
F
Recessed cooktop to countertop cutout
H
+
1
7
⁄
8
H
+
4.6
H
+
1
7
⁄
8
H
+
4.6
G
Countertop cutout to backsplash (min.)
1
⁄
2
1.3
1
⁄
2
1.3
H*
Rear overhang of cooktop
—
—
—
—
I
Top trim to backsplash (min.)
1
⁄
4
0.6
1
⁄
4
0.6
J
Vent box to back of cabinet (min.)
1
⁄
2
1.3
1
⁄
2
1.3
K
Depth of backsplash (max.)
3
⁄
4
1.9
3
⁄
4
1.9
e
Recommended junction box location
v
Recommended venting location
3
1
⁄
4
" x 10" (8.3 cm x 25.4 cm)
rectangular or 6" (15.2 cm)
diameter cutout
*Cooktop overhang will vary depending on model.
SIDE VIEW
CUTOUT DIMENSIONS
SIDE VIEW
36"/30" TELESCOPING DOWNDRAFT VENTILATION
JXD7036YS – 36" x 42
1
⁄
8
" x 12
1
⁄
8
"
JXD7030YS – 30" x 42
1
⁄
8
" x 12
1
⁄
8
"
v
A
B
C
E
D
Cooktop
Countertop
and Backsplash
Vent Box
F
G
I
J
H*
A
F
G
K
Centerline
of Cooktop
v
v
A
B
C
E
D
Cooktop
Countertop
and Backsplash
Vent Box
F
G
I
J
H*
A
F
G
K
Centerline
of Cooktop
v
v
A
B
C
E
D
Cooktop
Countertop
and Backsplash
Vent Box
F
G
I
J
H*
A
F
G
K
Centerline
of Cooktop
v
LOCATION REQUIREMENTS
Bull-nosed front edge countertops are not recommended. Some cooktop
and vent combinations may require a countertop deeper than 25" (63.5 cm).
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The vent is factory set for a 3
1
⁄
4
" x 10" (8.3 cm x 25.4 cm) rectangular
or a 6" (15.2 cm) diameter vent system venting through the wall or floor.
Do not terminate the vent in an attic or other enclosed area.
v
A
B
C
E
D
Cooktop
Countertop
and Backsplash
Vent Box
F
G
I
J
H*
A
F
G
K
Centerline
of Cooktop
v
TOP VIEW – CUTOUT
VENTILA
TION
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation or Use & Care Guide
before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.