background image

8

Electrical Requirements

Observe all governing codes and ordinances. 

Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 (latest 
edition), or CSA Standards C22.1-94, Canadian Electrical Code, 
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes 
and ordinances.

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 
required.

If the house has aluminum wiring, follow the procedure 
below:

1. Connect a section of solid copper wire to the pigtail 

leads.

2. Connect the aluminum wiring to the added section of 

copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of 
the appliance as specified on the model/serial rating plate. 
The model/serial plate is located behind the filter on the rear 
wall of the range hood.

Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.

INSTALLATION INSTRUCTIONS

Prepare Location

It is recommended that the vent system be installed before 
hood is installed.

If you are installing the optional backsplash with shelves for 
heat lamps, follow the instructions included with that product. 

Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for exhaust vent.

Check that all installation parts have been removed from the 
shipping carton.

1. Disconnect power.

2. Determine which venting method to use: roof or wall exhaust.

3. Select a flat surface for assembling the range hood. Place 

covering over that surface.

4. Using 2 or more people, lift range hood onto covered surface. 

Range Hood Mounting Screws Installation

The hood is attached to the wall with the wood support that is 
attached to the back of the hood.

1. Determine and mark the centerline on the wall where the 

canopy range hood will be installed.

2. Select a mounting height between a minimum of 30" 

(76.2 cm) and a suggested maximum of 36" (91.4 cm), above 
the cooking surface and the bottom of the range hood and 
mark a horizontal reference line on the wall.

3. Remove the wood support from the back of the range hood 

by loosening the 2 screws from the inside. Locate and level 
the top of the wood support 15

³⁄₈

" (39.1 cm) above the 

marked horizontal line and centered on the vertical centerline. 
Using 2 - 4 of the 6 x 80 mm screws, install wood support so 
that it is screwed into at least 2 vertical studs. 

NOTE: The screws provided for mounting this hood must be 
fastened into solid wood. Do not fasten into sheet rock only.

WARNING

Excessive Weight Hazard

Use two or more people to move and install 
range hood.

Failure to do so can result in back or other injury.

A. Wood support
B. Centerline

A

B

  30" (76.2 cm) 

to 36" (91.4 cm)

 

   15

³⁄₈

"

(39 cm) 

 

Содержание 30" (76.2 cm) Cooktop

Страница 1: ...U S A call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair com In Canada call 1 800 807 6777 or visit our website at www jennair ca Instructionsd installationetGuided utilisationetd e...

Страница 2: ...es 14 In Canada 14 WARRANTY 15 TABLE DES MATI RES S CURIT DE LA HOTTE DE CUISINI RE 17 EXIGENCES D INSTALLATION 19 Outillage et pi ces 19 Exigences d emplacement 19 Exigences concernant l vacuation 21...

Страница 3: ...instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all saf...

Страница 4: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Страница 5: ...LocationRequirements IMPORTANT Observe all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances...

Страница 6: ...9 cm Hood 12 32 5 cm for 36 91 4 cm Hood 9 24 9 cm for 30 76 2 cm Hood 18 45 7 cm 8 21 3 cm 9 25 0 cm 12 30 5 cm 18 45 7 cm 12 30 5 cm A B A 84 213 4 cm minimum for installations with canopy only B 9...

Страница 7: ...f the thermal break The break should be as close as possible to where the vent system enters the heated portion of the house Makeup air Local building codes may require the use of makeup air systems w...

Страница 8: ...tion and all local codes and ordinances INSTALLATION INSTRUCTIONS PrepareLocation It is recommended that the vent system be installed before hood is installed If you are installing the optional backsp...

Страница 9: ...Installation section 1 Using 2 or more people hang the range hood on the wall by placing the slotted holes in the range hood back over the 2 screws mounted to the wood support mounted to the wall NOT...

Страница 10: ...A Screw B Mounting hole A Blower motor mounting plate B Wire box connector C Power cord A B B C A A Terminal box cover B Knockout in canopy back into terminal box A White wires B Black wires C UL list...

Страница 11: ...on to use the range hood lights as a night light 2 Turn the light switch to the High position to turn the range hood lights On 3 Turn the light switch to the Off position to turn the range hood lights...

Страница 12: ...se Twist lamp clockwise to screw it into place 4 Repeat steps 2 and 3 for the other lamp if needed 5 Reconnect power Cleaning Exterior surfaces To avoid damage to the exterior surface do not use steel...

Страница 13: ...12ZA 9 Gnd BR Y Y G Y G BK W GY W W GY GY 2nd Motor in 48 121 9 cm 3rd Halogen Lamp in 48 121 9 cm MOTOR SPECIFICATIONS Power Supply 120 VAC Frequency 60 Hz Power Absorption 240 Watts Current MOTOR RE...

Страница 14: ...ber and serial number 3 Name and address of your dealer or servicer 4 A clear description of the problem you are having 5 Proof of purchase sales receipt User s guides service manuals and parts inform...

Страница 15: ...e service by an authorized Jenn Air servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance...

Страница 16: ...16 Notes...

Страница 17: ...n cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Страница 18: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Страница 19: ...0 x 50 mm Adaptateur TORX T20 Exigencesd emplacement IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Confier l installation de la hotte un technicien qualifi C est l ins...

Страница 20: ...121 9 cm 12 32 5 cm pour hotte de 36 91 4 cm 9 24 9 cm pour hotte de 30 76 2 cm 18 45 7 cm 8 21 3 cm 9 25 0 cm 12 30 5 cm 18 45 7 cm 12 30 5 cm A B A 84 213 4 cm minimum pour les installations avec h...

Страница 21: ...que possible de l endroit o le syst me d vacuation s introduit dans la partie chauff e de la maison Air d appoint Les codes de b timent locaux peuvent exiger l emploi d un syst me d appoint d air lors...

Страница 22: ...partie 1 et C22 2 n 0 M91 derni re dition et de tous les codes et r glements en vigueur INSTRUCTIONS D INSTALLATION Pr parationdel emplacement Il est recommand d installer le syst me d vacuation avan...

Страница 23: ...support en bois mont sur le mur dans la section Installation des vis de montage de la hotte 1 l aide d au moins 2 personnes suspendre la hotte au mur en pla ant les fentes de l arri re de la hotte sur...

Страница 24: ...des connecteurs de fils homologation UL A Compensateur ressort A Vis B Trou de montage A Plaque de montage du moteur du ventilateur B Raccord du bo tier de connexion C Cordon d alimentation A A B B C...

Страница 25: ...nfrarouges 3 Contr ler le fonctionnement du ventilateur de la hotte et des lampes Voir la section Utilisation de la hotte 4 Si la hotte ne fonctionne pas d terminer si un disjoncteur s est ouvert ou s...

Страница 26: ...rayons infrarouges REMARQUE Les ampoules pour lampes rayons infrarouges doivent avoir une intensit nominale maximale de 175 watts chacune 1 Placer le commutateur de la lampe infrarouge la position Hi...

Страница 27: ...isser des marques d eau Nettoyant et poli pour acier inoxydable D tergent liquide doux et eau Frotter avec un chiffon doux humide ou une ponge non abrasive puis rincer avec de l eau propre et essuyer...

Страница 28: ...JA VE N BL GRIS BL BL GRIS GRIS 2e moteur mod le 48 121 9 cm 3e lampe halog ne mod le 48 121 9 cm CARACT RISTIQUES DU MOTEUR Alimentation lectrique 120 VCA Fr quence 60 Hz Puissance nominale 240 Watts...

Страница 29: ...antie Si le marchand ou la compagnie de service ne peut pas r soudre votre probl me crivez Jenn Air Brand Home Appliances Customer eXperience Centre 200 6750 Century Ave Mississauga ON L5N 0B7 Adresse...

Страница 30: ...en Jenn Air autoris n est pas disponible 10 La d pose et la r installation de votre gros appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instruction...

Страница 31: ...31 Notes...

Страница 32: ...serv s Registered Trademark TM Trademark of Jenn Air U S A Used under license by Maytag Limited in Canada Marque d pos e TM Marque de commerce de Jenn Air U S A Emploi sous licence par Maytag Limited...

Отзывы: