(Installation)
Matters to be attended to before installation
Main source of electricity: AC220Volt, 1ph, 3Ampare
Cable connection: All cables need to be installed by being connected fast without being bent or
Twisted.
Install Punch Head
Installation should take place so that the distance between the Pin and the punching face should be
3.5~4.5mm with a deviation of ±10mm/
Valid marking distance: At PH16, 3.0~5.0mm.At LP10, 5.0~8.0mm
Valid air pressure: At PH16, 4.0kg/cm
2
~6kg/cm
2
, At LP10, 2.0kg/cm
2
~3kg/cm
2
Appropriate air pressure: AT PH16, 4.0~4.5kg/cm
2
, At LP10, 2.5~3.0kg/cm
2
Control marking quality: The quality of the marking products differ according to marking distance
and air pressure. At the Parameter Setup of MCU`s F4 screen, you can control the transfer
speed of pin. Also, you can choose the thickness of the pin edge-the Ball type is thick and deep,
the sharp type is thin or deep.
Refer to the drawing below to decide the installation location and the Pin interval.
X축
Y축
0점
ABCDEF
Marking Area
3~5mm 유지
소재
(Reference
1) (
Reference
2)
#. The closer the marking location is to 0, the operation time gets shorter.
Puncher sound level
In general, the puncher sound increases when the board is thin and the clamp is not steadily attached.
Sound cover attached: 55db, with silencer: under 50db
Puncher with weighty substance in open space: 72db with silencer: 56db
Puncher with a board less than 2 t in open space: 87db with silencer: 68db
Soundproof cover for a board less than 2 t in open space: 65db, with silencer: 50db이하.
8
Содержание Marksman MK-100N
Страница 5: ...Accessories Common CABLE Cable 15M CDC 20 Dip switch New NF 8785 T 300 5 ...
Страница 6: ...MARKING PIN LP 06 LP 10 LP 15 PH 16 LP 10 pin for Gun PLP 10 DIA_90D 6 ...
Страница 39: ...2 If you check on the Plot to file the file name will be archived 3 Create Plot file Set up the file name 39 ...
Страница 50: ...Advance programming 50 ...